37
-40.0 to 600.0°C
0.1°C
±(1.5% + 3°C)
600 to 1000°C
1°C
-40.0 to 600.0°F
0.1°F
±(1.5% + 5.4°F)
600 to 1800°F
1°F
Range Resolution
7.1.11. Temperature with K-Type Probe
Accuracy
Protection against overcharge: 1000V DC/AC rms
Instrument accuracy without probe; Specified accuracy with stable
environmental temperature at ±1°C.
For long-lasting measurements, reading increases by 2°C.
<1.5mA
3.3V DC
Test Current
Max Voltage with Open Circuit
7.1.12. Diode Test
Protection against overcharge: 1000V DC/AC rms.
≥
Uncertainty defined for: Voltage 10A; Below 2% of voltage range, add 20
counts.
1-25
20-75Hz
0.1% THD
±(5.0% + 20 digits)
Harmonic Order Base Wave Resolution Accuracy
Frequency
7.1.14. Current Harmonics
Protection against overcharge: 1000V DC/AC rms.
Uncertainty defined for: Voltage >10V; Below 2% of voltage range, add 20
counts.
1-25
20-75Hz
0.1% THD
±(5.0% + 8 digits)
1-8
75-400Hz
0.1% THD
±(6.0% + 8 digits)
Harmonic Order Base Wave Resolution Accuracy
Frequency
7.1.13. Voltage Harmonics
10.0%-90.0%
0.1%
±(1.2% + 8 digits)
Range Resolution
7.1.10. Duty Cycle
Accuracy
Pulse frequency range: 40Hz-10kHz; Pulse amplitude: ±5V (100s-100ms)