3.4.2. Relative Values
1. To activate the relative mode, press
and hold the F3 Key for more than
2 second to enter the selection
interface.
2. Press and hold the F1 Key to enter
relative measurement, the message
REL and symbol “Rel” appear on
the display.
3.4.3. MIN/MAX Values
1. Press and hold the F3 Key for more
than 2 second to enter the
selection interface.
2. Press the F3 Key again to enter
MAX MIN measurement, the
message “Max” and symbol “MAX
MIN” appear on the display.
3.4.4. Range Function
1. Into manual range and select range
of the measure.
2. If pressing the Range Button for
greater that 1 second will return to
Auto Range.
3.5.Individual Harmonic
Measurement Function
3.5.1. Voltage Measurement Mode
1. Press and hold the F3 Button for
more than 2 second to enter the
selection interface.
2. Press the F2 (Har) Button to enter
Harmonic Measurement, press the
F2 Button again to go back.
3. Press the F1 (<<) and F3 (>>)
Button to select symbol
“H01~H25”.