36
600.0A
0.1A
±(2.5% + 8 digits)
1000A
1A
±(2.8% + 8 digits)
Range Resolution
7.1.6. AC TRMS Current
Accuracy
Protection against overcharge: 1000A DC/AC rms.
Accuracy specified from 5% to 100% of the measuring range, sine wave.
Accuracy Inrush function integral time 100ms, and reading for reference only.
600.0Ω
0.1Ω
±(1.0% + 10 digits)
6.000kΩ
0.001kΩ
60.00kΩ
0.01kΩ
±(1.5% + 5 digits)
600.0kΩ
0.1kΩ
6.000MΩ
0.001MΩ
±(2.5% + 5 digits)
60.00MΩ
0.01MΩ
±(3.5% + 10 digits)
Range Resolution
7.1.7. Resistance and Continuity Test
Accuracy
Buzzer<50Ω; Protection against overcharge: 1000V DC/AC rms.
9.999-9.99kHz
0.01-10Hz
±(1.2% + 5 digits)
Range Resolution
7.1.8. Frequency (Electronic Circuits)
Accuracy
Protection against overcharge: 1000V DC/AC rms.
Sensitivity: >5Vrms (at 20%-80% duty cycle)
60.00nF
0.01nF
±(4.0% + 20 digits)
600.0nF
0.1nF
6.000μF
0.001μF
±(3.0% + 8 digits)
60.00μF
0.01μF
600.0μF
0.1μF
6000μF
1μF
±(5.0% + 8 digits)
Range Resolution
7.1.9. Capacitance
Accuracy
Protection against overcharge: 1000V DC/AC rms.