4.15. VFD Mode
1. Set the function switch to the
60A
or (
600A, 1000A
) Position to AC
Current measurement, or switch to the
V
Position to AC Voltage
measurement.
2. Press the
MODE/VFD
Button (2 second) to indicate “
VFD
” on the
display, to variable frequency driver measurements.
3. Read measurement on the display.
4.16. Hold Mode
• To freeze the display for any function, press the
HOLD
key.
• Press the
HOLD
key to release the freeze mode.
4.17. Capturing Minimum and Maximum Values
• The MAX/MIN Record mode captures minimum and
maximum input values.
• When the input goes below the recorded minimum
value or above the recorded maximum value, the
Meter beeps and records the new value.
• This mode is for capturing intermittent readings,
recording minimum and maximum readings
unattended, or recording readings while equipment
operation precludes watching the Meter.
• To activate the MAX/MIN mode, press the “ ” key.
• If the meter is already in MAX/MIN function,
press “ ” to turn off MAX/MIN function.