6.000V
0.001V
50Hz-60Hz: ±(1.2% + 5 digits)
60.00V
0.01V
61Hz-1kHz: ±(2.5% + 5 digits)
600.0V
0.1V
1000V
1V
Range Resolution
8.3.2. AC TRMS Voltage
Accuracy
Protection against overcharge: 1000VDC/ACrms.
Accuracy specified from 10% to 100% of the measuring range, sine wave;
Input impedance: > 9M
Ω
;
Accuracy PEAK function: ±10%rdg, PEAK response time: 1ms.
6.000V
0.001V
60.00V
0.01V
±(3.0% + 40 digits)
300.0V
0.1V
Range Resolution
8.3.3. LowZ AC TRMS Voltage
Accuracy
Input impedance: 300K
Ω
; Protection against overcharge: 1000VDC/ACrms.
Accuracy specified from 10% to 100% of the measuring range, sine wave.
6.000V
0.001V
60.00V
0.01V
50Hz-1kHz: ±(2.5% + 20 digits)
600.0V
0.1V
1000V
1V
Range Resolution
8.3.4. AC+DC TRMS Voltage
Accuracy
Input impedance>10M
Ω
; Protection against overcharge: 1000VDC/ACrms.
6.000V
0.001V
60.00V
0.01V
±(3.5% + 40 digits)
300.0V
0.1V
Range Resolution
8.3.5. LowZ AC+DC TRMS Voltage
Accuracy
Input impedance<300K
Ω
; Protection against overcharge: 1000VDC/ACrms.
41