7
Majestic • TRILLIANT25IN, TRILLIANT30IN, TRILLIANT35IN Installation Manual • 2571-980 Rev. B • 5/23
D. Inspect Appliance and Components
• Carefully remove the appliance and components from
the packaging.
• The vent system components, decorative barrier fronts
and surrounds are shipped in separate packages.
• If packaged separately, the log set and appliance grate
must be installed.
• Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
•
Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation to ensure maximum safety and benefit.
WARNING! Risk of Fire or Explosion!
Damaged parts
could impair safe operation.
DO NOT
install damaged, in-
complete or substitute components. Keep appliance dry.
Hearth & Home Technologies disclaims any responsibility for,
and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent
system component.
• Modification of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a fire hazard.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT
use this appliance if any part has been under
water. Call a qualified service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Tape measure
Pliers
Hammer
Phillips screwdriver
Voltmeter
Electric drill and bits (1/4 in.)
Gloves
Safety glasses
Level
Reciprocating saw
Manometer
Flat blade screwdriver
Stove cement / Aluminum foil tape
3/16 in. Allen wrench (Rear Leveling Legs)
Elongated pressure taps
(Recommended)
Noncorrosive leak check solution
Caulking material (300 ºF minimum continuous exposure
rating)
Figure 2.4 Good Faith Wall Surface Temperatures Above Appliance
B. Good Faith Wall Surface
NOTICE:
Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certification. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30
ºF or more
depending on the thermometer settings and material
characteristics being measured. Use appropriate finishing
materials that are able to withstand these conditions. For
additional finishing guidelines, see Section 8.
MEASUREMENTS FROM TOP
OF THE SURROUND OPENING
CEILING
APPLIANCE SURROUND
SURROUND
OPENING
18 IN.
22 IN.
16 IN.
12 IN.
24 IN.
28 IN.
34 IN.
40 IN.
46 IN.
52 IN.
151
º
F
138
º
F
135
º
F
127
º
F
125
º
F
120
º
F
115
º
F
110
º
F
108
º
F
106
º
F
If installing a television (TV) above the appliance, see