E. Hearth Extension / Vinyl Flooring
1/2 in.
Figure 3.18
Minimum Required 1/2 in. Gap to Bottom of Front
Mantels - Combustible
Figure 3.17 Minimum Vertical and Maximum Horizontal
Dimensions - Combustible
Measurement to bottom
of appliance:
= 29-1/4 in. (25")
= 32-3/4 IN. (30")
= 36-1/4 IN. (35")
Measurement
from surround
opening.
12 in.
12 in.
• All flooring and hearth material must remain below the
bottom of the surround. See Figure 3.19.
• Combustible flooring may be located in front of
the appliance. See Figure 3.20 for vinyl flooring
recommendations.
• 1/2 inch gap under the bottom of the front must be
maintained. See Figure 3.18.
• A minimum 1/4 inch gap from the bottom of the appliance
to the metal floor of the solid fuel firebox is
REQUIRED.
See side view in Figure 3.21.
• Combustible flooring underneath the appliance is
acceptable with a 1/4 inch gap. See Figure 3.21.
FLAME
SENSE IGNITER
TO POWER
CORD
110-120 VAC
FAN 110-120 VAC
RF MODULE
6V TRANSFORMER
PLUG
I
S
6 PIN
BRN
ORANGE
(PILOT)
GREEN
(MAIN)
IFT-RC400
REMOTE
CONTROL
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
APPLIANCE
ON/OFF
CONTROL
BRN
BLK
WIRE ASSEMBLY
BLK
RED
BLK
(OPTIONAL)
TO POWER CORD 110-120 VAC
(OPTIONAL)
ORANGE
WHITE
BACK VIEW
TOP VIEW
FRONT VIEW
SIDE
VIEW
POWER CORD
2550-013 (NG)
2550-014 (LP)
2326-131
2326-152
2326-130
2326-150
2179-300
2326-120
2166-302 (NG)
2166-303 (LP)
2326-132
GFK-160A
WSK-21-W
2159-310
2201-024
LIGHT WIRE
ASSEMBLY
2532-017
2201-150
HALOGEN BULBS (X 2)
NOT AN OPTION WITH 25 in. MODELS
2206-299
* MODULE RESET SWITCH
(LOCATED ON SURROUND)
* Reset switch must be installed
and in the “ON” position for
appliance to operate.
2187-198
BATTERY
PACK
2326-142
2532-301
Figure 3.19 Flooring & Hearth Material