A. General Information
WARNING! Risk of Shock or Explosion! DO NOT
wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE:
This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the
Canadian Electric
Code CSA C22.1.
• This appliance comes with a 110-120 VAC cord
assembly. This is required for proper operation of the
appliance (IntelliFire Touch
®
Ignition). An outlet box may
be installed in a bottom back corner of the
existing solid
fuel masonry or factory built fireplace
to plug in the cord
assembly, or the supplied power cord may be routed out
onto the hearth to a nearby outlet.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
• In some instances, the spark ignition of the fireplace may
cause intermittent, non-damaging, interference during
the lighting sequence with a TV plugged into the same
circuit. It is recommended that the fireplace and TV use
different circuits to mitigate the interference potential.
If interference is occurring on the same circuit, the use
of surge protectors may help alleviate the interference.
6
6
Electrical Information
Electrical Service and Repair
WARNING! Risk of Shock!
Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock!
Replace damaged wire with
type 105 ºC rated wire. Wire must have high temperature
insulation.
• Refer to Service Parts section of appliance Owner’s
Manual for replacement part information.
NOTICE: DO NOT
wire 110-120 VAC to wall switch.
Figure 6.1 Electrical Outlet Detail
ELECTRICAL OUTLET LOCATIONS
MASONR
Y
MASONR
Y
APPLIANCE
RECOMMENDED
Reset Switch
• A reset switch is included with the appliance surround
and should be attached to the side of the surround. See
Installation instructions shipped with the appliance front.
• Reset switch must be installed and in the “ON” position
for appliance to operate.
Appliance Size
Left Side
Right Side
25 in.
10 ft. 6 in.
8 ft.
30 in.
10 ft. 3 in.
7 ft. 6 in.
35 in.
10 ft.
7 ft.
Appliance Cord Length (approximate)