53D0419
1
Maximum
20"
FP2047
rear vent max horizontal
distance
Top View Flat Installation
REAR (THROUGH THE WALL) APPLICATIONS
When installed as a rear vent unit this appliance may be vented directly to a termination
located on the rear wall behind the appliance
• The maximum horizontal distance between the rear of the appliance and the outside
of termination is 20" (508 mm).
Figure 19
• Only one 45° elbow is allowed in these installations.
VENTING INSTALLATION
1.
Locate and cut the vent opening in the wall. For
combustible walls first frame in opening.
Combustible Walls:
Cut a 11
1
/
"H x 9
1
/
" W hole
through the exterior wall
. Figure 20
Noncombustible Walls:
Hole opening should be
7
1
/
" (190 mm) in diameter.
2, Rigid vent pipes and fittings have special twist-lock
connections. Assemble the desired combination
of pipe and elbows to the appliance adapter with
seams oriented towards the wall or floor.
Twist-lock Procedure:
The female ends of the
pipes and fittings have three locking lugs (indenta-
tions). These lugs will slide straight into matching
slots on the male end of adjacent pipes and fittings.
Push the pipe sections together and twist one sec-
tion clockwise approximately one-quarter turn until
the sections are fully locked.
Figure 21
3. Attach the vent pipe assembly to the fireplace. Set
fireplace in front of its permanent location to insure
minimum clearances. Mark the wall for an 11
1
/
"
H x 9
1
/
" W (292 x 241 mm) rectangular hole (for
noncombustible material such as masonry block or
concrete, a 7
1
/
" (190 mm) diameter hole is accept-
able).
Figure 20.
The center of the hole should
align with the center line of the horizontal rigid vent
pipe end. Be sure to allow for minimum rise. Cut
an 11
1
/
" x 9
1
/
" (292 x 241 mm) rectangular hole
through combustible exterior wall (7
1
/
" (190 mm)
diameter if noncombustible.) Frame as necessary.
Allow 1/4" minimum rise per foot.
Figure 20
Figure 19 - Rear Vent Application, Maximum
Horizontal Distance
FP2048
FP2049
rigid vent pipe
Note: Horizontal runs of vent
must be supported every three
feet (914 mm). Use wall straps
for this purpose.
Figure 21 -
Rigid Vent Pipe Connections
Female
Locking Lugs
Male Slots
FP2049
FP2050
vent openings
Figure 20 -
Exterior Wall Framing Dimensions
9
1
/
"
(241 mm)
11
1
/
"
(292 mm)
7
1
/
"
(190 mm)
4
1
/
"
(121 mm)
FP2050