CLEARANCES
CLEARANCES TO COMBUSTIBLES
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel requirements listed in this manual.
W
ARNING
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible material
other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall
be installed on a metal, wood or noncombustible material panel extending full width
and depth of the appliance.
V
W
X
Y
Z
A B C D E
FP2040
mantel clearances
10/08
Figure 11 -
Clearances
Mantel Shelf Chart (Minimum Height)
Ref. Mantel Depth Ref. Height Above Louvres
V
10 (254 mm)
A
12" (305 mm)
W
8" (203 mm)
B
10" (254 mm)
X
6" (152 mm)
C
8" (203 mm)
Y
4" (102 mm)
D
6" (152 mm)
Z
2" (51 mm)
E
4" (102 mm)