73D0129
9
DVKHL Series Gas Fireplace
72” (1829 mm)
Minimum
Ceiling
12”
(305 mm)
Max. Depth
2
1
/
2
” Max Depth
(64 mm)
10” (254 mm)
Min.From Opening
16” (406 mm)
Min. From Opening
FP2128
mantel clearances
6”
(152 mm)
Min.
Hearth 8” Min.
(203 mm)
Noncombustible
Hearth Minimum
Fireplace Opening
cLearanceS
cLearanceS tO cOMBuStIBLeS
ManteL cLearanceS
nOte: the combustible area above the facing must not protrude more than 3/4" from the facing. If it
does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Figure 4 - Clearances from the mantel,
ceiling, and side wall.
6"
5"
3"
2
1
/
2
"
4
1
/
2
"
45°
1"
3
1
/
2
"
FP2129
mantel leg
1
1
/
2
"
FP2129
Fireplace Opening
Figure 5 -
Mantel clearances
top View
w
arn
In
G
Follow these instructions carefully to ensure safe installation. Failure to
follow instructions exactly can create a fire hazard.
the appliance cannot be installed on a carpet, tile or other combustible
material other than wood flooring. If installed on carpet or vinyl flooring,
the appliance shall be installed on a metal, wood or noncombustible
material panel extending full width and depth of the appliance.
12"
(305 mm)
16"
(406 mm)
10"
(254 mm)
12" (305 mm)
6" (152 mm)
2
1
/
2
" (64 mm)
FP2204
mantel clearances
Wall
Stud
Insulation
Board
Standoff
Top of Fireplace
Opening
FP2235
Side View
FP2128