background image

23

CR Series Woodburning Fireplaces

20001316

LIMITED WARRANTY & 30 YEAR PROTECTION PLAN

For MAJESTIC FIREPLACES

®

 PRE-ENGINEERED Fireplace Systems

CFM Corporation warrants its MAJESTIC FIREPLACES® Pre-
Engineered  Fireplace  (“Fireplace”)  and  the  CFM  Corporation 
supplied firegrate, glass doors, outside air system, fan motor, 
and liners to be free from defects in material or workmanship, 
as follows:

A. Fireplace and Chimney Components:

 (exclusive of CFM 

Corporation-supplied firegrate, glass doors, outside air system, 
fan motor, and liners all of which are covered by separate war-
ranties under paragraphs B through D below): At its option for a 
period of thirty (30) years from the date the Fireplace is installed, 
CFM Corporation will;
1.  For a period of five (5) years from the date the Fireplace is 

installed, CFM Corporation, at its option, will repair or replace 
any defective part without charge.

2.  Thereafter,  through  the  10th  year  after  the  date  the  Fire-

place is installed, if replacement parts are available, CFM 
Corporation will provide a replacement for any defective part 
without charge for the part itself.  The consumer must pay 
for everything else other than the part.

3.  Thereafter, through the 30th year after the date the Fireplace 

is installed, if replacement parts are available,CFM Corpora-
tion will provide a replacement for any defective part at a cost 
to the consumer of CFM Corporation then current list price, 
FOB CFM Corporation factory.

B. Firegrate, Glass Doors, Outside Air System:

For a period of 90 days from the date the Fireplace is installed 
CFM Corporation, at its option, will provide a replacement for 
any defective part, without charge for the part itself, FOB CFM 
Corporation factory, (The consumer must pay for everything else 
other than the part,).

C. Fan Motor:

1.  For a period of one (1) year from the date the Fireplace is 

installed, CFM Corporation, at its option, will repair or replace 
any defective part without charge.

2.  Thereafter, through the 30th year after the date the Fireplace 

is  installed  CFM  Corporation,  at  its  option,  if  replacement 
parts are available, will provide a replacement for any defec-
tive part at a cost to the consumer of CFM Corporation then 
current list price, FOB CFM Corporation factory.

D. Liners (Refractory or Metal):

1.  For a period of two (2) years from the date the Fireplace is 

installed, CFM Corporation, at its option, will repair or replace 
any defective part without charge.

2.  Thereafter, through the 30th year after the date the Fireplace 

is installed CFM Corporation, if replacement parts are avail-
able, will provide a replacement for any defective part at a 
cost to the consumer of CFM Corporation then current list 
price, FOB CFM Corporation factory.

This warranty is subject to the following conditions and limita-
tions:
1.  This warranty is extended only to a Fireplace installed in the 

continental United States, the state of Alaska and Canada; 
only if and so long as the Fireplace is installed or serviced by a 
qualified installer, preferably NFI or WETT (Canada) certified, 
and according to the installation instructions furnished with 

the Fireplace, and operated at all times under normal condi-
tions, use and service according to the operative instructions 
furnished with the Fireplace, and only if and so long as the 
Fireplace is not removed from its original installation.

2.  This warranty is non-transferrable, and is made to the original 

owner,  provided  that  the  purchase  was  made  through  an 
authorized supplier of the Company.

3.  The sole and exclusive remedies for breach of any warranties 

hereunder shall be for the repair, replacement or provision 
of a replacement part at CFM Corporation then current list 
price, FOB CFM Corporation  factory, for any defective part 
as specified in paragraphs A through D.

4.  CFM Corporation shall not be liable for damage from any 

smoking  of  a  MAJESTIC  FIREPLACES  Pre-Engineered 
Fireplace  System  related  to  environmental  geographic 
conditions (such as, for example, nearby structures or roof 
peaks, trees, hills, or mountains), inadequate ventilation, or 
negative air pressure in the place where the Fireplace system 
is installed, related to any mechanical system (such as, for 
example,  furnaces,  fans,  air  conditioners,  clothes  dryers, 
etc.)

5.  Except  as  otherwise  expressly  specified  in  paragraphs A 

through D, NONE OF THESE WARRANTIES COVER, AND  
CFM CORPORATION SHALL NOT BE RESPONSIBLE FOR, 
ANY CONSTRUCTION, INSTALLATION, LABOR, TRANS-
PORTATION OR OTHER COSTS OR EXPENSES ARISING 
FROM A DEFECTIVE PART, ITS REPAIR OR REPLACE-
MENT OR OTHERWISE, NOR SHALL CFM CORPORATION 
IN ANY EVENT BE RESPONSIBLE FOR ANY INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES EXCEPT 
TO THE EXTENT REQUIRED BY LAW.  Some states do not 
allow the exclusion or limitation of incidental or consequential 
damages,  so  this  exclusion  or  limitation  may  not  apply  to 
you.

NO  IMPLIED  WARRANTIES,  INCLUDING  THE  IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR 
A PARTICULAR PURPOSE, SHALL REMAIN IN EFFECT AF-
TER THE EXPIRATION OF THE WARRANTIES SET FORTH 
IN PARAGRAPHS A THROUGH D.  Some states do not allow 
limitations on how long an implied warranty lasts, so this limita-
tion may not apply to you.
In  order  to  obtain  performance  of  any  of  the  above  warranty 
obligations write to CFM Corporation at this address:
   

CFM Corporation

   

410 Admiral Blvd.

   

Mississauga, Ontario, Canada L5T 2N6

   

Attention: Director of Warranty Services

Since local building requirements may vary greatly throughout 
the country, users of CFM Corporation products should deter-
mine in advance whether there are any building code restrictions 
on the use of a specific product. CFM CORPORATION MAKES 
NO REPRESENTATION OR WARRANTY REGARDING, AND 
SHALL NOT BE RESPONSIBLE FOR, ANY BUILDING CODE 
COMPLIANCE.
The foregoing warranties give you specific legal rights and you 
may also have other rights which vary from state to state.

Summary of Contents for CR36R

Page 1: ...R36R CR36L CR Series Corner Woodburning Fireplace DO NOT DISCARD THIS MANUAL Retain for future use For use in U S Canada Underwriter s Laboratories Report No MH6018 20001316 4 07 Rev 14 Homeowner s In...

Page 2: ...ed or approved by CFM Corpo ration in combination or assembly with a CFM Corporation replace system notwithstanding any independent testing laboratory or other third party approval of such component p...

Page 3: ...m 21 545mm 172mm 36 914mm 40 1019mm 1054mm Gas Line Access 9 241mm 8 203mm 7 178mm 14 362mm 4 Dia Outside Air Collar Rough Opening Height CR36R L Series Woodburning Fireplace Fig 1 CR36R L Series spec...

Page 4: ...n Grate Firebox Outside Air Control Outside Air Cover Plate Gas Access See Figure 20 on page 15 for clearance information Outer Dome Ceiling Level Firestop Batt Insulation cut out around restop Fig 2...

Page 5: ...himney exit at top CR36L R Series Maximum 90 0 Minimum Without elbows 14 0 With 2 elbows 15 0 With 4 elbows 21 0 B Do not use more than four elbows per chimney Attach the straps of the top elbows to a...

Page 6: ...the surface of the roof a distance of 10 3 m from the chimney in a horizontal plane The top of the chimney must be at least 2 610 mm above the reference point but never less than 3 914 mm in height a...

Page 7: ...ossible Insulate base of replace with a non combus tible insulation rated for a minimum of 300 F Insulating is very important for outside wall installations over a concrete slab If replace is installe...

Page 8: ...and indicate dimension X to locate the side wall framing Fig 8 Be sure to observe clearance requirements for side and parallel combustible walls as noted in Figure 20 Page 15 FP555CR Insulation 2 26 9...

Page 9: ...rip must be fabricated and used to protect combustible surfaces in front of the replace This Z shaped safety strip is not provided but must be fabricated of metal with each horizontal leg at least 1 3...

Page 10: ...alling the Firestop Spacer in the Ceiling Hole A restop spacer is used to keep pipe spaced properly and required for safety Nail the restop spacer at each corner to the framing members of the ceiling...

Page 11: ...insulation is planned to be used in the attic Install the attic insulation shield with the anges on its base extending down into the framing hole Nail each corner of attic insulation shield to the fra...

Page 12: ...predetermined height Check the chimney top installation instructions for details on how high above the roof top the chimney sections all pipes should extend Installing Top Housing or Termination Foll...

Page 13: ...59mm Min 12 305mm Max 12 305mm Max 7 16 1 1 Fig 18 Fireplace surround ush with nished wall FE101a Combustible Mantel and Trim Mantel Clearance No Noncombustible Facing Material Mantel Clearance with N...

Page 14: ...lle CERAFORM 126 K 27 1 2 thick re quired 2 CFM Corporation Building Products EH2416 K 458 1 thick required Hearth Installation A hearth extension is required to protect a combustible oor in front of...

Page 15: ...bustible deco rative covering OR 018 Min Sheet Metal Combustible Floor Minimum Insulation Value R Fireplace Hearth FS108 Sealing Sides 6 22 99 djt Safety Strips must be Overlapped Min Seal Crack Betwe...

Page 16: ...seal between the pipe and the tube NOTE The gas pipe should not come in contact with any wood structures until it has reached a point at least one 1 inch away from the replace side NOTE Local codes m...

Page 17: ...42 20001183 5a Screen Rod Finished 90 7554156 7554155 5b Screen Rod Finished Straight 7554181 7554181 6 Screen Pulls two per replace 5584139 5584139 7a Firebrick Side 20000793 20000794 7b Firebrick Ba...

Page 18: ...he system If you use an unapproved component or make any modi cations you may possibly cause a re hazard and will void the CFM Corporation warranty In addition such action may void the coverage provid...

Page 19: ...alvanized steel unit Roof ashing is included Appropri ate adapter is required See Sections 2 and 3 Required to extend Traditional Top Housings on steeply pitched roofs Used to terminate chimney at the...

Page 20: ...n the roof Flashing not included For use with CFM Corporation Type SK8 Chimney Systems Used to terminate chimney at the top of a chase Adapter kit included Flashing not included 8 6 12 8 ue 0 to 6 12...

Page 21: ...25r Adapter kit CTSK42 3 5 99 djt Chase Top Adapter Kit Hearth Patching Kit 325p r P325p Chase top housings SKDSBL PKDSBL 4 28 99 djt Accessories for Canada Accessory Description Model No Attic Insula...

Page 22: ...22 CR Series Woodburning Fireplaces 20001316...

Page 23: ...installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed or serviced by a quali ed installer preferably NFI or WETT Canada certi ed...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: