background image

2

CR Series Woodburning Fireplaces

20001316

Safety Information

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.
IMPORTANT: 

Read all instructions and warnings carefully before starting installation.  Failure to 

follow these instructions may result in a possible fire hazard and will void the warranty.

Description

The CR36R/L Series fireplaces are multi-sided solid fuel, 
woodburning fireplaces. These are radiant models only 
and include a preinstalled outside air kit.

Precautions

CFM Corporation fireplaces and component parts have 
been highly tested and will operate safely when installed 
in accordance with instructions provided in this manual. 
Carefully read and understand all instructions 

before

 

beginning installation.
If you notice any damage to fireplace or component parts, 
immediately report damage to your Majestic Fireplaces 
dealer.
Only use CFM Corporation components or the warranty 
will be voided and a fire hazard may be created.
CFM Corporation warranty will be voided by and CFM 
Corporation disclaims any responsibility for the following 
actions:

• 

Installation by any other than a qualified install-
er, preferably NFI or WETT (Canada) certified.

• 

Installation of any damaged fireplace or chim-
ney component;

• 

Modification of fireplace, chimney assembly or 
any component parts thereof; 

(except for chase 

flashings as detailed in the Chimney Top installa-
tion instructions).

• 

Installation other than as instructed by CFM 
Corporation; or

• 

Installation and/or use of any component part 
not manufactured or approved by CFM Corpo-
ration in combination or assembly with a CFM 
Corporation fireplace system, notwithstanding 
any independent testing laboratory or other 
third party approval of such component parts 
or accessory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in 
compliance 

before 

installing the fireplace.

Fireplaces must be vented to the out-of-doors.

Do not obstruct or modify air inlets/outlets in any 
manner. 
Do not install combustible materials on any of the 

black fireplace surround.
Burn only solid wood fuel or gas logs.
Do not install a solid fuel burning insert or other 
products not specified for use with this fireplace.

Safety Information ......................................... 2
Specifications and Framing ........................... 3
Parts Identification  ........................................ 4
Chimney Requirements  ................................ 5
Planning Information ..................................... 6
Installation  .................................................... 7
Replacement Parts ...................................... 17
Accessories  ................................................ 18

Table of Contents

Drafts

The fireplace should not be located in areas that create 
drafts (ie: frequently opened doors and central heating air 
inlets/outlets) that hamper the normal flow of air into the 
fire.

Gas Logs

If you plan to install a gas log, the gas line should be 
installed 

before

 framing the fireplace. The gas line must 

be installed by a certified gas line installer.

Proposition 65 Warning:

 Fuels used in gas, wood-

burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known to 
the State of California to cause cancer, birth defects 
and other reproductive harm.
California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufacturer 
before installing a television or other electronic de-
vice above this fireplace.

CR36R / CR36L

Listed

UL / ULC-S610

Standard for Factory Built Fireplaces

Summary of Contents for CR36R

Page 1: ...R36R CR36L CR Series Corner Woodburning Fireplace DO NOT DISCARD THIS MANUAL Retain for future use For use in U S Canada Underwriter s Laboratories Report No MH6018 20001316 4 07 Rev 14 Homeowner s In...

Page 2: ...ed or approved by CFM Corpo ration in combination or assembly with a CFM Corporation replace system notwithstanding any independent testing laboratory or other third party approval of such component p...

Page 3: ...m 21 545mm 172mm 36 914mm 40 1019mm 1054mm Gas Line Access 9 241mm 8 203mm 7 178mm 14 362mm 4 Dia Outside Air Collar Rough Opening Height CR36R L Series Woodburning Fireplace Fig 1 CR36R L Series spec...

Page 4: ...n Grate Firebox Outside Air Control Outside Air Cover Plate Gas Access See Figure 20 on page 15 for clearance information Outer Dome Ceiling Level Firestop Batt Insulation cut out around restop Fig 2...

Page 5: ...himney exit at top CR36L R Series Maximum 90 0 Minimum Without elbows 14 0 With 2 elbows 15 0 With 4 elbows 21 0 B Do not use more than four elbows per chimney Attach the straps of the top elbows to a...

Page 6: ...the surface of the roof a distance of 10 3 m from the chimney in a horizontal plane The top of the chimney must be at least 2 610 mm above the reference point but never less than 3 914 mm in height a...

Page 7: ...ossible Insulate base of replace with a non combus tible insulation rated for a minimum of 300 F Insulating is very important for outside wall installations over a concrete slab If replace is installe...

Page 8: ...and indicate dimension X to locate the side wall framing Fig 8 Be sure to observe clearance requirements for side and parallel combustible walls as noted in Figure 20 Page 15 FP555CR Insulation 2 26 9...

Page 9: ...rip must be fabricated and used to protect combustible surfaces in front of the replace This Z shaped safety strip is not provided but must be fabricated of metal with each horizontal leg at least 1 3...

Page 10: ...alling the Firestop Spacer in the Ceiling Hole A restop spacer is used to keep pipe spaced properly and required for safety Nail the restop spacer at each corner to the framing members of the ceiling...

Page 11: ...insulation is planned to be used in the attic Install the attic insulation shield with the anges on its base extending down into the framing hole Nail each corner of attic insulation shield to the fra...

Page 12: ...predetermined height Check the chimney top installation instructions for details on how high above the roof top the chimney sections all pipes should extend Installing Top Housing or Termination Foll...

Page 13: ...59mm Min 12 305mm Max 12 305mm Max 7 16 1 1 Fig 18 Fireplace surround ush with nished wall FE101a Combustible Mantel and Trim Mantel Clearance No Noncombustible Facing Material Mantel Clearance with N...

Page 14: ...lle CERAFORM 126 K 27 1 2 thick re quired 2 CFM Corporation Building Products EH2416 K 458 1 thick required Hearth Installation A hearth extension is required to protect a combustible oor in front of...

Page 15: ...bustible deco rative covering OR 018 Min Sheet Metal Combustible Floor Minimum Insulation Value R Fireplace Hearth FS108 Sealing Sides 6 22 99 djt Safety Strips must be Overlapped Min Seal Crack Betwe...

Page 16: ...seal between the pipe and the tube NOTE The gas pipe should not come in contact with any wood structures until it has reached a point at least one 1 inch away from the replace side NOTE Local codes m...

Page 17: ...42 20001183 5a Screen Rod Finished 90 7554156 7554155 5b Screen Rod Finished Straight 7554181 7554181 6 Screen Pulls two per replace 5584139 5584139 7a Firebrick Side 20000793 20000794 7b Firebrick Ba...

Page 18: ...he system If you use an unapproved component or make any modi cations you may possibly cause a re hazard and will void the CFM Corporation warranty In addition such action may void the coverage provid...

Page 19: ...alvanized steel unit Roof ashing is included Appropri ate adapter is required See Sections 2 and 3 Required to extend Traditional Top Housings on steeply pitched roofs Used to terminate chimney at the...

Page 20: ...n the roof Flashing not included For use with CFM Corporation Type SK8 Chimney Systems Used to terminate chimney at the top of a chase Adapter kit included Flashing not included 8 6 12 8 ue 0 to 6 12...

Page 21: ...25r Adapter kit CTSK42 3 5 99 djt Chase Top Adapter Kit Hearth Patching Kit 325p r P325p Chase top housings SKDSBL PKDSBL 4 28 99 djt Accessories for Canada Accessory Description Model No Attic Insula...

Page 22: ...22 CR Series Woodburning Fireplaces 20001316...

Page 23: ...installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed or serviced by a quali ed installer preferably NFI or WETT Canada certi ed...

Page 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: