MIEN5208 Series Managed Industrial Ethernet Switch
- 5 -
Power input:
The DC power supply model of the MIEN5208 series switches supports
DC12~48V power supply, supports dual power input, and the two power
supplies are backup each other.
The AC power supply model of MIEN5208 series switches supports
DC110V~370V and AC85V~264V power supply. When using AC model, V can
only input from V1+ and V1-, V1+ is connected to fire line L, V1-connected to
zero line N, please do not V2+, V2- access, and pay attention to safety to
prevent electric shock.
Power failure alarm output
The MIEN5208 series switches support the alarm function, with a normally
open node and a normally closed node. The left side is a normally open node,
the right side is a normally closed node, and the middle one is a common end.
When the switch works normally, the normally open node is powered on and
closed, and the normally closed node is disconnected. When the system is
powered off, the port is dropped, or the ring network is alarmed, the normally
open node is powered off and the normally closed node is closed. The relay
recommended switch load capacity is 1A (24VDC). The user can use the relay
contact to output other external sound and light alarm devices.
RELOAD button
MIEN5208 series switches are equipped with 1-position button switch.
After long press for 5s, the device will automatically restore the factory settings.
3.1.2. LED indicator lights
The LED indicators on the front panel of the MIEN5208 series switch can
show the status of the system operation and port, which is easy to find and
solve the fault.
Description of the LED indicator
LED
Conditio
ns
Status
System status LED
PWR1/ PWR2
on
The power is connected and working
properly
off
The power is unconnected or working
abnormal
RUN
blinking
The system is running normally
off
The system is running abnormal
RING
on
Ring open
off
Ring close
Fiber port status LED
LINK
On
The port has established an active