Additional CSA-B366.1 1-11 Requirements for Add-Ons to Gas-Fired Furnaces
5.7 Additional CSA-B366.1 1-11 Requirements for Add-Ons to Gas-
Fired Furnaces
There are additional requirements in Canada for adding a solid fuel fired furnace to operate when connected
to a gas fired furnace.
5
5..7
7..11 O
Op
pe
erra
attiio
on
n V
Ve
erriiffiie
ed
d
Each gas furnace must be verified for acceptable operation BEFORE and AFTER being connected to an add-
on appliance by a gas fitter who is recognized by the authority having jurisdiction.
5
5..7
7..2
2 E
Ex
xiissttiin
ng
g G
Ga
ass--F
Fiirre
ed
d C
Ce
errttiiffiic
ca
attiio
on
n R
Re
eq
qu
uiirre
em
me
en
ntt
Do not connect to any furnace that has not been certified initially as complying with ANSI Z21.47/CSA2.3 or
its precedents.
5
5..7
7..3
3 B
Bllo
ow
we
err rre
eq
qu
uiirre
em
me
en
ntt
Do not connect to any furnace that is not equipped with an air circulation blower.
5
5..7
7..4
4 C
Ch
hiim
mn
ne
ey
y
Do not connect, under any circumstances, to the chimney or vent serving a gas furnace or gas appliance.
5
5..7
7..5
5 D
Du
uc
cttw
wo
orrk
k
Do not connect ductwork so that a reverse flow is possible.
5
5..7
7..6
6 P
Pe
erriio
od
diic
c O
Op
pe
erra
attiio
on
n
Operate the gas-fired unit periodically to ensure that it will operate satisfactorily when needed.
5
5..7
7..7
7 S
Sa
affe
etty
y C
Co
on
nttrro
ollss
Do not relocate or bypass any of the safety controls in the original furnace installation.
5
5..7
7..8
8 G
Ga
ass ffu
urrn
na
ac
ce
e ffu
urrtth
he
err c
co
om
mp
plliia
an
nc
ce
e
The gas furnace installation shall comply with the applicable requirements of CSA B365, and if changes are
made to the gas furnace, including clearances for servicing, these shall comply with CSA B149.1 or CSA
B149.2.
PE 603 USA_FA 1.0
Summary of Contents for AutoPellet Air TOUCH 17
Page 42: ...42 Cable routing PE 603 USA_FA 1 0...
Page 43: ...Cable routing 43 Installation Manual AutoPellet Air Furnace 17 28...
Page 45: ...Wiring diagrams 45 Installation Manual AutoPellet Air Furnace 17 28...
Page 46: ...46 Wiring diagrams PE 603 USA_FA 1 0...
Page 47: ...Wiring diagrams 47 Installation Manual AutoPellet Air Furnace 17 28...
Page 70: ...70 Pellet Furnace cautionary markings PE 603 USA_FA 1 0...
Page 71: ...Pellet Furnace cautionary markings 71 Installation Manual AutoPellet Air Furnace 17 28...
Page 72: ...72 Pellet Furnace cautionary markings Labeling 105x74 PE 603 USA_FA 1 0...
Page 73: ...Pellet Furnace cautionary markings 73 Installation Manual AutoPellet Air Furnace 17 28...
Page 74: ......
Page 75: ......