7.4 Frost protection temperatures
An internal frost protection monitoring
prevents the heat exchanger from freezing
up at low external temperatures.
Temperature sensors continually register
the temperature on the heat exchanger
and of the outside air.
7.4.1 WS 170 comfort and bypass unit
Frost protection is ensured using the
internal frost protection heating register
integrated in the outside air channel of
the ventilation unit.
7.4.2 WS 170 standard unit
The supply air fan switches off if the outgoing
air temperature downstream of the heat
exchanger falls below the preset "Frost
protection switch-off point".
The supply air fan only switches on again
when the temperature increases to the set
"Frost protection switch-off point".
A detailed description of how to set the
switch-on and switch-off points is provided
in the WS 170 installation instructions.
8. Accessories
Accessory / Product type
Article no.
10x WSG 170 air filter,
class G4
0093.0270
Push-in frame WSG-ES 170
for G4 air filter
0093.0269
1x WSF 170 pollen filter,
class F7
0093.0271
1x WSF-AKF 170
active carbon air filter,
class F7
0093.0272
Temperature sensor with
grommet NTC 15
0157.0833
RLS 1 WR
room air control
0157.0809
RLS D1 WR
digital control
0157.0828
HY 5
hygrostat
0157.0123
SKD
CO
2
sensor
0157.0345
VOC sensor:
EAQ 10/2 air quality controller
0157.0834
Combi wall support, right-hand
version, suitable for WS 170 R,
WS 170 KR and WS 170 KBR
KWH 12 R
KWH 16 R
0152.0058
0152.0060
Combi wall support, left-hand
version, suitable for WS 170 L,
WS 170 KL and WS 170 KBL:
KWH 12 L
KWH 16 L
0152.0059
0152.0061
Plug connector with lip seal
SVR 125
0055.0183
B90-125
pipe elbow
0055.0312
Summary of Contents for WS 170 L
Page 3: ......
Page 20: ...de 9 Ersatzteile 18 9 Ersatzteile...
Page 38: ...uk 9 Spare parts 36 9 Spare parts...
Page 58: ...fr 9 Pi ces de rechange 56 9 Pi ces de rechange...