4. Safety instructions and warnings 

 

4. Safety instructions and  

          warnings 

NOTICE 

Indicates a possible situation, 

which could cause damage to 

the product or its surroundings. 

 

The external shutter must not be used in 

the following situations under any circum-

stances. 

 

Risk of combustion/fire from 

flammable materials, liquids or 

gases in the vicinity of the unit. 

Do not 

place any flammable materials, liquids or 

gases near the external shutter, which may 

ignite in the event of heat or sparks and catch 

fire. 

 

Explosive gases and dusts may 

ignite and cause serious explosions 

or fire.

 Never use external shutters in an 

explosive atmosphere (risk of explosion). 

 

Risk to health from chemicals or 

aggressive gases/vapours. 

Chemicals 

or aggressive gases/vapours may harm 

health, especially if they are distributed 

throughout the rooms by the external shutter. 

Never use external shutter as a duct shutter 

for chemicals or aggressive gases/vapours. 

 

Grease and oil vapours from range 

hoods may contaminate the external 

shutter and reduce efficiency. 

Never use 

external shutter in combination with range 

hoods with exhaust air operation. 
 
 
 
 
 
 
 
 
 
 

Observe all safety instructions. 

 

Risks for children and 

people with reduced 

physical, sensory or mental 

capabilities or a lack of 

knowledge. 

External shutter 

may only be installed, 

commissioned, cleaned and 

maintained by people who can 

safely recognise and avoid the 

risks associated with this work. 

 

Risk of injury due to 

suction and rotating 

impeller of a connected fan.

 

Hair, clothing, jewellery etc. may 

be pulled in if you get too close 

to the fan. During operation, 

always keep far enough away to 

prevent this from happening. 

 

Danger of injury if foreign 

bodies are inserted into 

the unit. 

Do not insert any 

objects in the unit. 

 

Summary of Contents for MK 20

Page 1: ...lektrische Au enklappen Mounting instructions Electric external shutters Notice de montage Volets ext rieurs lectriques MK 20 MK 25 MK 31 MK 20 S MK 25 S MK 31 S BK 20 BK 25 BK 31 www m aico ventilato...

Page 2: ...Elektrizit t erkennen und vermeiden k nnen 3 Bestimmungsgem e Verwendung Elektrische Au enklappen als Verschluss klappen f r L ftungskan le Wandh lsen etc Zur Kombination mit z B EN ENR Ventila toren...

Page 3: ...wenn diese ber die Au enklappe in die R ume verteilt werden Au enklappe auf keinen Fall als Kanalverschluss f r Chemikalien oder aggressive Gase D mpfe einsetzen Fett und ld mpfe von Dunstabzugs haube...

Page 4: ...o Wohneinheit betr gt 4 Pa Die Ausf hrung bedarf grunds tzlich der Zustimmung des Bezirksschornsteinfegers Gefahr durch Stromschlag bei Be trieb mit besch digter Au enklappe Au enklappe nicht demontie...

Page 5: ...380 135 5 BK 20 200 325 218 275 83 BK 25 250 370 262 320 105 5 BK 31 315 430 320 380 135 5 8 Montage ACHTUNG Au enklappe schlie t nicht korrekt falls diese verspannt eingebaut wird Um die Klappenfunkt...

Page 6: ...men 10 Inbetriebnahme bereinstimmung mit den technischen 1 Daten kontrollieren Typenschild Sicherstellen dass die Luft ungehindert 2 str men kann Netzsicherung einschalten Warnschild 3 entfernen Funkt...

Page 7: ...ise and avoid risks and dangers associated with electricity on the basis of your technical training and experience 3 Intended use Electric external shutters as shutters for ventilation channels wall s...

Page 8: ...ially if they are distributed throughout the rooms by the external shutter Never use external shutter as a duct shutter for chemicals or aggressive gases vapours Grease and oil vapours from range hood...

Page 9: ...is 4 Pa The consent of a professional chimney sweep is needed in all cases Danger of electric shock when operating with damaged external shutter Do not dismantle external shutter Only operate the ext...

Page 10: ...rnal shutter does not close properly if it is tensely installed To ensure the shutter functioning only mount the external shutter on a flat surface Make sure there is sufficient space to the wall or c...

Page 11: ...ng plate Ensure that the air can flow unobstructed 2 Switch on mains fuse remove warning sign 3 Run function test When doing so check 4 for correct closing and opening functions 11 Cleaning If require...

Page 12: ...tilisation conforme Volets lectriques ext rieurs comme volets de fermeture pour gaines de ventilation gaines murales etc utiliser par ex en combinaison avec les ventilateurs EN ENR Ces derniers sont p...

Page 13: ...le volet ext rieur Ne jamais utiliser le volet ext rieur pour diffuser des produits chimiques ou gaz vapeurs agressifs Des vapeurs de graisse et d huile en provenance de hottes aspirantes risquent d...

Page 14: ...gle g n rale l accord du ramoneur responsable de votre district Danger d lectrocution en cas d exploitation d un volet ext rieur endommag Ne pas d monter le volet ext rieur N utiliser le volet ext rie...

Page 15: ...31 315 430 320 380 135 5 BK 20 200 325 218 275 83 BK 25 250 370 262 320 105 5 BK 31 315 430 320 380 135 5 8 Montage ATTENTION Le volet ext rieur ne ferme pas correctement lorsqu il a t mont sous cont...

Page 16: ...e Version selon classe de protection II D sactiver le fusible secteur s curiser 1 contre toute remise en service intempestive et apposer un panneau d avertissement Effectuer le branchement lectrique...

Page 17: ...n emballage contient des mat riaux recyclables qui ne doivent pas tre limin s avec les ordures m nag res liminez les mat riaux d emballage dans le respect de l environnement conform ment aux prescript...

Page 18: ...itch ENR 20 25 31 BK 20 25 31 ou MK 20 25 31 avec interrupteur Marche Arr t et commutateur inverseur S1 Ein Aus S2 Umschaltung Entl ftung Bel ftung Klemme 5 Entl ftung Klemme 6 Bel ftung Leitung nur f...

Page 19: ...r f r Au enklappe MK WH wei BU blau BN braun S1 On Off Cable only for MK shutter WH white BU blue BN brown S1 Marche Arr t Conducteur uniquement seulement pour trappe MK WH blanc BU bleue BN marron S1...

Page 20: ...MAICO Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 6940 technik maico de 07 17_Es 0185 0209 0001_RLF 7_07 17_DSW...

Reviews: