UK │ 1. Scope of delivery
14
1. Scope of delivery
●
Fan unit with internal climate sensor
●
External shutter with external climate
sensor and sensor connection cable
●
Two sealing strips
●
These mounting and operating instructions
2. General notes
Read these mounting instructions
carefully before using the AKE.
Follow the instructions. Keep these
instructions safe for use later on.
2.1 Installation staff
Mounting is only permitted when carried out
by trained specialists.
Only qualified electricians are permitted to
make the electrical connections. They are
trained in electrical engineering and are
aware of the risks and consequences of an
electric shock.
2.2 Symbols used
DANGER
Direct risk of danger. Failure to
observe will result in severe
injury or death.
CAUTION
Possibly dangerous situation
which could result in minor to
moderate injuries.
NOTICE
Possible situation which could
cause damage to the product or
its surroundings.
INFO symbol indicating
important information and tips.
●
Bullet point for information on the
respective subject.
1.
Instructions. Follow the
instructions given in the order
stated.
3. Product information
3.1 Unit overview, Figure A
1 Housing with motor
2 Impeller
3 Designer cover
4 Cover
5 Internal grille
6 Internal climate sensor
7 Electronics cover
8 Electronic circuit board
9 Cable grommet – recessed-mounted
connection
10 Cable grommet – surface-mounted
connection
11 External climate sensor with sensor
connection cable
12 External shutter
3.2 Product description
AKE 150
is a small room fan for dehumidi-
fying rooms, especially cellars and other
similar rooms. The unit has a fixed internal
grille and is equipped with an integrated
internal climate sensor. A controlled dehumi-
dification takes place based on the compa-
rison between the room climate and the out-
door climate. To do this, an external shutter
with an integrated external climate sensor
MUST be connected. To aid in the room de-
humidification, an aeration fan from AKE 150
can directly be controlled at the same time.
Function of the dehumidification control
The controlled ventilation dehumidifies the
rooms (cellars) through targeted removal of
humid room air and simultaneous supplying
of dry outside air.
To do so, the absolute humidity (aH), as a
measure for the water vapour content in the
air, is determined by both climate sensors
(those for interior and exterior spaces).
This measurement takes place immediately
after switching on the unit. As soon as the ab-
solute outside humidity falls below the abso-
lute inside humidity (aH
outer
< aH
inner
) the fan
of the AKE 150 is automatically activated and
a dehumidification period begins (active time).