5. Set-up of the grinder
A grinding test run is carried out on each grinder in our factory.
This is why you may find ground material residue in the grinding
mechanism!
You have received your grinder in operating condition. Now you
only need to connect the grinder to the mains plug. Proceed as
follows:
5.1 Usage Location
Place the grinder on a level, vibration-free surface. The grinder
is often used in rooms where there is water and humidity, and
therefore it must be properly insulated.
Never operate the grinder in moist, or even
worse, in wet surroundings!
5.2 Electrical connection of grinder
Connect the grinder to an earthed 230V 16A wall outlet.
The machine must be connected to an earthed
power outlet! Always observe the rules in effect
in the user’s country.
4. Safety Devices of the Grinder
Motor protector
The winding of the motor is protected by a thermal switch
(thermo pill/bimetal), which will trip when the motor heats up
significantly. The grinder cannot be started again. Let it rest for
appr. 30 minutes. The thermal switch will re-connect the motor
automatically.
The user has no influence whatsoever on these
circuit breakers. If the circuit breaker trips
repeatedly, an authorised service partner must
be consulted, as the motor’s winding may be
damaged.
Finger protector / Magnet holder
A combined finger protector / magnet holder is fitted in the
hopper of the grinder. It is supposed to prevent the user from
reaching into the running grinding mechanism. At the same
time, it also prevents ferrous foreign objects from getting into the
grinding mechanism. Every now and then clean the magnet since
adhering foreign objects could block the coffee supply.
Never remove the finger protection!
G A S T R O N O M I E M Ü H L E N | H O R E C A G R I N D E R
8