2.5.3  Nitrogen purity tester

The Nitrogen purity tester can be used to determine the percent 
of nitrogen produced by the NTF-515B by connecting to the test 
port on the right side of the unit. It can also be used to measure 
the percent of nitrogen in the tires after performing a service.

 

t

Refer to the operation manual for the purity tester (035-81169-
00) for further details.

Fig. 7: 

N

2

 purity analyzer

 

t

When using the purity tester to measure nitrogen purity in a 
tire, you can minimze the pressure loss, and corresponding 
refill requirements, by removing the tester from the valve stem 
after a sample has been obtained. The reading continues to 
climb after the tester has been removed - this is due to the 
response time of the internal sensor. Once the rate of change  
of the reading slows down or stabilizes, reapply the tester to 
the valve stem to obtain another sample.

 

m

Always recheck the tire pressure when purity testing is com-
plete and replenish nitrogen as necessary.

2.5.4  Locking caster brakes

Rolling of the NTF-515B can be prevented by locking the caster 
brakes (Fig. 1, Pos. 5) at the rear wheels.

2.5.5  Battery and battery charger

The NTF-515B is powered by a 12V, 7AH battery mounted inside 
the cabinet. There is a battery charger connection port located 
on the left hand side of the unit.

The NTF-515B is switched on by toggling the rocker switch to 
the On position.

 

m

Do not leave NTF-515B unit powered on overnight as draining 
the battery below 9V could cause damage to the battery cells.

Fig. 8: 

Battery charger

2.5.6  Dually hose connection

The NTF-515B includes an additional connection port at the top 
of the unit on the back (Fig. 2, Pos. 1). This port is utilized if the 
Dually tire fill accessory kit is purchased and allows the filling of 
6 tires simultaneously. MSS P/N 355 80123 00.

Fig. 9: 

Dually hose connection kit

2.5.7  Single tire fill accessory connection port

The NTF-515B includes an extra connection port on the back of 
the unit (Fig. 2, Pos. 3). Some technicians prefer to use a digital 
tire fill gauge to top off a tire instead of allowing the unit to fill the 
tire. Technicians can connect their own coiled hose and digital 
tire fill gun to the unit if they own one. In the instance that one is 
not available, MSS has P/N 355 80258 00 available for purchase.

Summary of Contents for NitroPRO NTF-515B

Page 1: ...MAHLE NTF 515B EN Operation Manual Nitrogen Tire Filling Unit...

Page 2: ...fill accessory connection port 11 2 6 Functional description 12 2 6 1 Unit function 12 2 6 2 Nitrogen generation 12 2 7 Commissioning 13 2 7 1 Removing transportation packaging 13 2 7 2 Verify air sou...

Page 3: ...MAHLE 3 en...

Page 4: ...erating MAHLE products it is absolutely essential that the Original instructions owner s manual and in particular the safety instructions are studied carefully By doing so you can eliminate any uncert...

Page 5: ...haser to operate and maintain MSS equipment according to instructions in the MSS Operation Manual for the covered product MSS provides free technical support over toll free telephone lines in the USA...

Page 6: ...instructions or normal operating procedure d Any damage to product during original shipment or subse quent shipments to MSS s facility for service e Portions of products which are subject to warrantie...

Page 7: ...ts and other contaminants Do not place the NTF 515B in a room where organic solvent vapors may be present y y Oil content of the compressed air should be less than 0 01mg m3 y y Ensure that the compre...

Page 8: ...essed air not exceeding 150 PSI Excess pressure could damage mem brane and other internal components m mCheck filters daily prior to use to ensure clean dry air is being fed to the membrane Damage may...

Page 9: ...5 or 98 8 Oil filter with automatic drain 9 Nitrogen membrane Fig 3 Front control panel 1 Air inlet pressure gauge 2 Power switch 3 Main display LCD 4 Tank pressure LCD 5 button 6 button 7 START butto...

Page 10: ...and release silver clip N N To remove the air chuck from the valve stem press down on the silver clip and pull off of valve stem Fig 6 Air chuck 2 4 User interface 2 4 1 Selection and function keys K...

Page 11: ...NTF 515B can be prevented by locking the caster brakes Fig 1 Pos 5 at the rear wheels 2 5 5 Battery and battery charger The NTF 515B is powered by a 12V 7AH battery mounted inside the cabinet There is...

Page 12: ...or exit and the NTF 515B inlet so that the hot compressed gas has time to cool within the specifications listed in this manual A higher membrane pressure will increase the capacity i e nitrogen output...

Page 13: ...temperature is below 110 F m mIf your application requires an inlet pressure of 100 119PSI the pressure value can be adjusted to accomodate the lower system pressure Contact MSS Technical Support at...

Page 14: ...etween the gauge reading and the display 3 1 1 Over pressure setting OPS and nitrogen purge cycles N2P The Over Pressure Setting can be used to improve the nitrogen purity in the tire s The Over Press...

Page 15: ...2321 3 5 Nitrogen purge cycle N N Process can be used for single or multiple tires 1 Attach air supply 150PSI max to the NTF 515B 2 Turn on POWER switch PCB will display battery charge status HI or L...

Page 16: ...of filter housing for water or oil 3 If a float is not functioning it may be submerged in water oil N N If a float is found to be inactive follow the cleaning procedure N N If necessary a replacement...

Page 17: ...the filter housing Fig 13 Pos 1 5 Unscrew the blue knob Fig 13 Pos 4 6 Remove the old filter element Fig 13 Pos 3 7 Clean the sieve Fig 13 Pos 2 filter bowl and the filter housing if necessary 8 Insta...

Page 18: ...355 80094 00 Service hose assembly 24ft 355 80095 00 Battery charger power cord 025 80436 00 Battery charger 026 80636 00 Battery charger and cord 355 80204 00 Battery 12VDC 040 80220 00 Automatic dra...

Page 19: ...MAHLE Notes 19 en 5 Notes...

Page 20: ...2017 09 21 035 82548 00 MAHLE Aftermarket Inc 10 Innovation Drive York PA 17402 USA 717 840 0678 www servicesolutions mahle com...

Reviews: