© MAHLE
Product description | NTF-515B | 9
NTF-515B | 9
| 9
en
2.3
Description of unit
Fig. 1:
Front view
1 Top tool tray and storage
2 Front control panel
3 Front tool tray and storage
4 NTF-515B front housing
5 Locking caster
6 Handle grip
7 Purity test port
8 Hose hook
9 Rear wheel
Fig. 2:
Rear view
1 Dually tire hose accessory quick connect
2 Air inlet connection
3 Water filter with automatic drain
4 Single tire digital fill gun accessory quick connect
5 Automatic drain (oil and water)
6 Carbon filter
7 Purity selector valve (95% or 98%)
8 Oil filter with automatic drain
9 Nitrogen membrane
Fig. 3:
Front control panel
1 Air inlet pressure gauge
2 Power switch
3 Main display LCD
4 Tank pressure LCD
5 "+" button
6 "-" button
7 "START" button
8 "N2" button
The pressure gauge (Fig. 3, Pos. 1) of the front control panel is
used to monitor the air inlet pressure. The N2 pressure inside the
tank is displayed on the lower LCD screen (Fig. 3, Pos. 4). The
status of the phases during service is displayed on the upper
LCD screen (Fig. 3, Pos. 3). The necessary entries are made by
way of the touch sensitive keys (Fig. 3, Pos. 5-8) .
The power switch (Fig. 3, Pos. 2) shuts the power off to conserve
the battery. It also functions as the main power to the air inlet
solenoid.