background image

© MAHLE

 

 

 

 

9  Service Menu 

 

 

To  carry  out  calibration  the  service  kit  (tooling  set) 
described at chapter 10 is required. 

 

9.1 

Manual activations and analogue 
channel view 

 

From  the  SECURED  SERVICE  menu,  (insert  the  password 
“BRN”),

  select  MANUAL  ACTIVATIONS  and  press  START, 

insert  the  password  “

BRN

”,  press  RETURN  and  then  enter 

OK. 
This submenu allows controlling the actuators and displays 
all measurements. 

Fig. 15:  Manual activations screen

 

 
As shown in the picture the activated actuators are 
highlighted with 

green

 background colour. If deactivated 

the colour is 

red

The corresponding chart can be found in the APPENDIX
 
At the bottom you can select the following functions:

 

Pneumatic schema 

 

Screen rotation (useful if the front door is open)

 

Close menu (

red

 square) 

 
Manual Activation Key 

(in bold the names 
used in this manual)

 

Actuators of 
the Pneumatic 
Schema (see 
APPENDIX 1) 

Power Board 
Output (see 
APPENDIX

OUT A 

A1, A2 

OUT A 

OUT R 

R1, R2 

OUT R 

OUT L 

L1 

OUT L1 

OUT T 

T1 

OUT T1 

OUT S

 

OUT S

 

OUT I

 

OUT I

 

OUT N

 

OUT N

 

OUT V1 

V1, V2, V 

OUT V 

OUT C

 

OUT C

 

OUT L2 

L2 

OUT L2 

OUT H

 

OUT H

 

OUT T2 

T2 

OUT T2 

OUT X 

Not Used 

OUT X 

 
 
 

| AIR-

calibration  the  service  kit  (tooling  set) 

Manual activations and analogue 

SERVICE  menu,  (insert  the  password 

MANUAL  ACTIVATIONS  and  press  START, 

RETURN  and  then  enter 

This submenu allows controlling the actuators and displays 

 

. If deactivated 

APPENDIX. 

At the bottom you can select the following functions: 

Screen rotation (useful if the front door is open) 

Power Board 

(see 

APPENDIX 4) 

 
 

 

 

 

 

 

 

9.2 

Pressures calibration (service kit)

 

From  the  SECURED  SERVICE  menu,  (insert  the  password  “

select  PRESSURE  CALIBRATION  and  press  START
messages, and enter OK to confirm. 
Disconnect the LP and HP quick couplers from any A/C system and 
press enter OK. 
Wait some minutes until the sentence “Emptying hoses” disappears.
Then  the  message  asks  to  connect    to  LP  hose  the 
adapter  (alone,  not  connected  to  the  bottle)
station accessories kit; when the next message is displayed,.

 

Fig. 16:  LP quick coupler opening

 

 

Turn the LP quick coupler clockwise to open it and press enter OK
so that air gets into the LP hose 
 
Wait  for  the  message  to  connect  the  reference  gauge  contained  in 
the  service  kit  and,  by  rotating  LP  counter  clockwise,  close  and 
remove the bottle fitting adapter. 
 
 
 
WARNING:      
BE  SURE  BEFORE  TO  CONFIRM,  THAT  BOTTLE  FITTING 
ADAPTER HAS BEEN REMOVED FROM LP QUICK COUPLER.
 
Connect to HP coupler the reference gauge present in the SERVICE 
KIT,  open  the  HP  quick  coupler  by  rotating  it  clockwise  and  press 
enter OK. 

 

WARNING:      
ATTENTION  NOT  TO  POINT  THE  REFERENCE 
ONESELF  OR  OTHER  PEOPLE  UNTIL  ONE  HAS  THE  ABSOLUTE 
CERTAINTY THAT THE

 

CONNECTION WITH THE QUICK COUPLER 

IS SAFE.  
 
OPEN  THE  TAP  OF  THE  QUICK  COUPLER  BY  POINTING  THE 
GAUGE  TOWARDS  THE  GROUND,  ALWAYS  KEEP  THE  GAUGE 
TOWARDS  THE  GROUND  EXCEPT  WHEN  THE  GUIDED 
PROCEDURE  REQUIRES  ENTERING  THE  VALUE  DISPLAYED  ON 
THE SAMPLE GAUGE. 

 

 

 

 
 
 
 
 
 
Fig. 17:  Reference gauge connection 
 
                                                            Fig. 18:  

 

 

-NEX 9380/9480 | 15    en

 

calibration (service kit) 

SERVICE  menu,  (insert  the  password  “BRN”),

 

and  press  START,  read  the 

Disconnect the LP and HP quick couplers from any A/C system and 

some minutes until the sentence “Emptying hoses” disappears. 

connect    to  LP  hose  the  bottle  fitting 

(alone,  not  connected  to  the  bottle),  included  in  the  ACX 

station accessories kit; when the next message is displayed,. 

 

P quick coupler clockwise to open it and press enter OK

 

Wait  for  the  message  to  connect  the  reference  gauge  contained  in 

and,  by  rotating  LP  counter  clockwise,  close  and 

BE  SURE  BEFORE  TO  CONFIRM,  THAT  BOTTLE  FITTING 

REMOVED FROM LP QUICK COUPLER. 

gauge present in the SERVICE 

P  quick  coupler  by  rotating  it  clockwise  and  press 

REFERENCE  GAUGE  TOWARDS 

PEOPLE  UNTIL  ONE  HAS  THE  ABSOLUTE 

CONNECTION WITH THE QUICK COUPLER 

OPEN  THE  TAP  OF  THE  QUICK  COUPLER  BY  POINTING  THE 
GAUGE  TOWARDS  THE  GROUND,  ALWAYS  KEEP  THE  GAUGE 
TOWARDS  THE  GROUND  EXCEPT  WHEN  THE  GUIDED 

S  ENTERING  THE  VALUE  DISPLAYED  ON 

 

 

 

:  Reference gauge reading

 

Summary of Contents for AIR-NEX 9380

Page 1: ...MAHLE AIR NEX 9380 9480 EN Service Manual A C Service Equipment...

Page 2: ...7 10 Equipment and simulator 17 11 Refrigerant fluid circuit 17 11 1 Refrigerant fluid circuit 17 11 2 Operational cycles 17 11 3 Receiving tank refrigerant cylinder 17 11 4 Manifold charts 18 11 5 Su...

Page 3: ...bal warming of the planet The release of refrigerant gas R134a into the atmosphere is forbidden by laws that were enacted within the framework of the Kyoto protocol For information only we will mentio...

Page 4: ...th an original spare part or equivalent by a MAHLE centre Before opening the service station extract completely the supply cable from the plug or you can get an electric shock Do not tamper with or by...

Page 5: ...g repairing it 2 3 Safety devices The A C service station is equipped with the following safety devices SAFETY PRESSURE SWITCH in case of excessive pressure SAFETY VALVE The safety valve opens when th...

Page 6: ...val of possible polluting substances from the A C system or parts of it Non condensable gas Refrigerant stored in gaseous phase including air and nitrogen 3 4 Guidelines for the handling of refrigeran...

Page 7: ...ed Refrigerant recovery and recharging Vacuum generation Flushing 4 2 Scope of delivery Description Service hose high pressure Service hose low pressure Quick release coupling high pressure Quick rele...

Page 8: ...ollowing icons are available on the display Icon Description Device connected via WiFi The residual refrigerant weight in kg and with visual bar to enable disable the bar by vertically swiping your fi...

Page 9: ...Vehicle selection OneClick Cycles Additional Functions Maintenance Setup Secured Service not available for user reserved only for customer service personnel Each function will be described in the nex...

Page 10: ...ype 13 18bar 1 4SAE Trip pressure 18 bar PED category Dir 2014 68 EU IV Pneumatic fittings Net length of external HP and LP hoses 4 5 m HP and LP pressure gauges Analog 80 mm pulse free 1 0 class Disp...

Page 11: ...imum devices required for correct handling shall be ensured as provided for by accident prevention provisions POSITIONING Place the unit in a stable place The location must be well ventilated with a g...

Page 12: ...plunger shall remain upright to be able to transfer liquid refrigerant for this type of tanks connect to the L liquid coupler Tanks without plunger have only one valve so they must be turned upside do...

Page 13: ...UV dye bottle Fig 1 Pos 9 it has to be extracted from its housing by means of the quick coupler on the top of the bottle slightly press downward the coupler ring nut to extract it standard UV Dye UV...

Page 14: ...in the garage data to be printed at the bottom of the cycle report LANGUAGE by selecting this entry any language present in the database may be set In case you choose a language with unintelligible c...

Page 15: ...apter alone not connected to the bottle station accessories kit when the next message is displayed Fig 16 LP quick coupler opening Turn the LP quick coupler clockwise to open it and press enter OK so...

Page 16: ...r opening Turn the LP quick coupler clockwise to open it and press enter OK so that air gets into the LP hose Wait for the message to connect the reference gauge contained in the service kit and by ro...

Page 17: ...nt fluid circuit 11 1 Refrigerant fluid circuit For components and circuit layout ref APPENDIX 1 REFRIGERANT FLUID CIRCUIT 11 2 Operational cycles For components and circuit layout ref APPENDIX 2 OPER...

Page 18: ...system and closed that a pipe emptying operation has been made and the manifold has been completely emptied Fig 21 Manifold components NOTE on the manifold drawing above the position of the pressure s...

Page 19: ...product can get its maximum performance in terms of hold resistance For one s own and other people s safety the operator user of the Loctite 577 product must consider that it must be employed in well...

Page 20: ...AINTENANCEfromtheMAIN MENU press and scroll to MAINTENANCE and then select Fig 26 Maintenance screens Only for model AIR NEX 9380 REFRIGERANT TYPE CHANGE With this function allows the service assistan...

Page 21: ...to determine and store the at pressure value We recommend running this procedure every time the A C service station will be moved from a location to another with a different altitude 14 6 Self leak te...

Page 22: ...eplacement comply with the instructions outlined below 1 disconnect the HP and LP hoses from other systems circuits or vehicles and close the quick couplers 2 wait the ends the hoses emptying 3 confir...

Page 23: ...the lid of the printer as shown note press the green led as in picture and only after that open the lid 2 Position the roll of paper inside the housing in the rotation direction indicated in the pictu...

Page 24: ...dies in charge after the results of the previous checks performed of commissioning or not establish different The checks must be performed by the bodies in charge in the country where the station is c...

Page 25: ...c components for use of R1234yf He will also carry nfigurations and verifications required by the the MAINTENANCE 14 16 Replacing white sample filter Refrigerant identification unit The need to replac...

Page 26: ...electronic power board Replacement of power supply board 15 2 Extraordinary maintenance 15 2 1 Replacement of component connected to refrigerant circuit The components pressurised equipment constituti...

Page 27: ...Evident damage to board components and circuits For the replacement of the board it is recommended to position the new board alongside the one to be replaced Disconnect and reconnect the cables in se...

Page 28: ...OF A C SERVICE STATION AIR NEX 9380 9480 ECO LOCK optional LP quick coupler and red Active Oil Protection kit 2 pcs New Oil 1 UV dye rts are available through the Service Centers USING NON ORIGINAL UN...

Page 29: ...en 29 AIR NEX 9380 9480 APPENDIX 1 REFRIGERANT FLUID CIRCUIT AIR NEX 9380 9480 H...

Page 30: ...AIR NEX 9380 9480 30 en APPENDIX 2 REFRIGERANT FLUID CIRCUIT AIR NEX 9380 9480 OPERATIONAL CYCLES Uncondensable gases H...

Page 31: ...en 31 AIR NEX 9380 9480 Recovery cycle H...

Page 32: ...AIR NEX 9380 9480 32 en Vacuum H...

Page 33: ...en 33 AIR NEX 9380 9480 Recharge H...

Page 34: ...Dye1 input load cell dye 1 10 LC New Oil1 input load cell new oil 1 11 PS Tank input pressure sensor tank 12 LC Ex Oil input load cell 13 PS LP input pressure sensor LP 14 PS HP input pressure sensor...

Page 35: ...EX 9380 9480 APPENDIX 4 AIR NEX 9380 9480 ELECTRICAL CONNECTION POWER ELECTRONIC BOARD AND POWER SUPPLY POWER ELECTRONIC BOARD POWER SUPPLY BOARD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21...

Page 36: ...ed oil draining 9 OUT H Heat exchanger fan 10 OUT I HP LP solenoid interconnection valve 11 OUT N Solenoid valve for draining of tank s uncondensable gases 12 OUT V Vacuum pump 13 OUT V Vacuum solenoi...

Page 37: ...ing to the 20 minutes vacuum time Gas leakage from internal or compressor check for leaks from valves R or check compressor functioning Pressure sensor not Altitude compensation and or full pressure c...

Page 38: ...Change vacuum pump oil When the filter capacity is the filter capacity is finished Change filter with new one During the setting of the inner tank charge amount Amount required greater than that avai...

Page 39: ...disconnected or damaged To check electrical connections or change with new spare part During vacuum bottle filling or leak test phase in vacuum The vehicle A C system is pressurized Recover the refrig...

Page 40: ...le fittings leak test Empty the vehicle follow the procedure guided by the displayed messages A048 HP LEAKAGE During the gas recovery and hoses emptying phase At the end of the gas charging in the E3...

Page 41: ...is phase Analisys not possible Check with virgin refrigerant bottle if the refrigerant gas identifier is working properly If yes and the refrigerant of the car is not R1234yf empty in a safety way and...

Page 42: ...MAHLE Aftermarket Italy S p A Via Quasimodo 4 a 43126 Par ma ITALY 2019 11 07...

Reviews: