EN | 30 | ACX150/250 | Maintenance
© MAHLE
4.
Before opening the doors of
the equipment, switch off
the equipment and
disconnect the power
supply cord.
DANGEROUS VOLTAGE HAZARD
5.
Remove the six screws that
fix the front door of the unit.
6.
Unscrew the 2 connection
nuts of the filter by means of
the hex keys.
7.
Remove the straps that
wind up the filter
8.
Install the new filter paying
attention to the position of
gaskets and to the direction
of the arrow indicating the
fluid flowing direction.
9.
Screw the two connection
nuts of the filter.
10.
Replace the front panel
11.
Carry out the automatic leak
test requested by the
software when switched on
again after the filter
replacement.
14.10
System info
In the main menu select MAINTENANCE
and press “INFO”.
In the INFO page, at any time, the
software version and the serial number
can be displayed.
14.11
System update
The firmware (software) can be
updated by way of a USB stick.(where
the new version is stored).
1.
Insert the USB stick in
USB port (fig.3 pos.4)
2.
Power on ACX150/250.
3.
In the main menu select
MAINTENANCE and
press “SYSTEM
UPDATE”.
4.
A message will appear
that the unit is loading
an update.
5.
The unit may load an
updated language file,
database file and
configuration file while
updating.
6.
Once unit is updated,
the software version
string on the
introduction screen
during power up will
change.
NUTS
DRYER FILTER