16 Series, Model - 2816 HST
109
Element Cleaning
Use clean, dry compressed air up
and down the pleats on the clean
side (inside) of the element.
Continue this until the element is
clean.
NOTE:
1.
The paper element must be
handled with care. Do not hit the
element against a hard surface.
2. Air pressure at the nozzle must not exceed 689 kPa (100 PSI).
3. It may be necessary to replace the element sooner if the time interval
between servicing becomes short indicating the element does not
respond to cleaning (soot contaminated).
DUMP VALVE
System Inspection
Check the dump valve and the all hoses for cracks and wear. Replace if
needed. All the connections on the hoses must be tight. All the gaskets
must be in good condition and the bolts must be drawn up tight.
NOTE:
Inspect the hoses and connections after the first 50 hours of
operation and replace when necessary.
LUBRICATION/FILTERS/FLUIDS _____________________________________________