34
BA364601-en
Display
Diagnostics
Remedy
DOWN button and UP
button and red fault
indicator flash more than
10 times.
Configuration mode.
Notify service team.
Red fault indicator flashes,
blue DOWN button is lit.
Electrical emergency stop
activated.
Lower the lift.
Red fault indicator light and
blue UP/DOWN buttons are
permanently lit.
Internal fault.
Turn off main switch and
switch on again after approx.
5 seconds. Notify service
team if the fault reoccurs.
8
Repairs
See repair instructions in the lift's technical handbook.
9
Decommissioning, Dismantling and Disposal
Decommissioning and dismantling of the equipment may be done only by
specially authorized and trained personnel provided by the manufacturer,
licensed dealers or service partners.
Pay attention to the product and safety data sheets of the lubricant used. Avoid
damage to the environment. Should a disposal of the device be necessary it
must be done in adherence with locally applicable legal regulations regarding
environmental protection. Remove all materials properly sorted out and bring
them to a suitable waste disposal service. Collect operating materials such as
grease, oils, coolant, solvent-based cleaning fluids etc. in suitable containers
and dispose of in an environmentally protective manner.
Alternatively, you may take the equipment to a specialised waste management
plant to ensure that all components and operating liquids are properly disposed
of.
10
Declaration of Conformity
See following page(s).
Summary of Contents for MA STAR 5.5
Page 1: ...MA STAR 5 5 Two Post Lift Original Operating Instructions BA364601 en...
Page 11: ...BA364601 en 11 2 3 2 Installation Diagram MA STAR 5 5 Standard...
Page 14: ...14 BA364601 en 2 3 5 Installation Diagram MA STAR 5 5 Slim...
Page 17: ...BA364601 en 17 2 3 8 Installation Diagram MA STAR 5 5 Wide...