Intervention in the Automatic Testing Procedure
Drive slowly and straightly onto the brake tester with the axle which is to be tested again. Both
sensor rollers must be pushed down. Release brake and place gear shift to neutral. The screen
below will appear. Instruction line:
)
Please wait
and then
)
Please brake
1 Select <FA>, <PB>, <RA> (or <F2>, <F3>)
to change between the displays for front,
rear, and parking brake.
2 The
box
“Testing“ in the upper right-hand
corner of the screen shows for which brake
the test can be repeated.
3 The ovality test can be repeated with <F4>.
)
Ovality test, Maintain brake force
Wait until the timer has run out.
4 Delete the temporary storage with <DEL> .
)
Delete temporary measurement values
5 Use <F8> to set the displayed
measurement value as max. measurement
value if , for example, the vehicle has not
reached the preset slip.
)
Maximum values
6 Use <F9> to file the displayed
measurement values in the temporary
storage for brakes which are shown in the
box “Testing“.
)
Maximum values
)
Store m. values in FA (PB, RA)
The measurement values can only be changed as long as the measurement values are still in
the temporary storage.
If the measurements are already stored with customer and vehicle data after the test procedure
(section 4.2.6 “
Storage of the Test
Values“
), after-the-fact changes are no longer possible. In
this case the test will have to be done again.
Summary of Contents for FWT 1 Euro
Page 19: ...Eurosystem Profi LON Safety 2 4 D1 E101BA1 GB09...
Page 39: ...Eurosystem Profi LON Profi LON Operation 3 20 D1 E101BA1 GB09...
Page 119: ...Eurosystem Profi LON Maintenance Troubleshooting 5 8 D1 E101BA1 GB09...
Page 128: ...Appendix Eurosystem Profi LON D1 E101BA1 GB09 6 9 6 2 Short Instructions...
Page 129: ...Eurosystem Profi LON Appendix 6 10 D1 E101BA1 GB09...
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......