Eurosystem / Profi-LON
PC Program Operation
4.64
D1 E101BA1-GB09
3 Brake effectiveness test left
a. Start the left hand roller set via the
Motor-On-key of the remote control.
⇒
The left hand roller set runs forward, the
right hand roller set runs in the reverse
direction.
Motor left
Motor right
b
= Motor off
c
= Motor on
b. Ovality test (if desired) see paragraph
„Ovality test“
.
c.
Slowly press the brake pedal until the
rollers switch off.
⇒
The roller drive switches off as soon as
the pre-set slip is reached.
Slip is not reached?
If the brake force of the vehicle brake is not enough to reach slip, then the roller drive is
switched off with the Motor-Off-key of the remote control.
⇒
The max.brake force is displayed by the left hand bar.
d. Release brake pedal immediately.
⇒
The measured max. brake force is shown by the left-hand bar.
⇒
The right hand bar remains at zero.