87
MCT PARAMETER ALARM
ALARM CODE:23
Problem: Cycle time exceeds previous cycle time by
value set in MCT parameter.
The MCT parameter when used, monitors sequential cycle times and
alarms if a cycle time exceeds the previous cycle time by an amount
that is not consistent with proper operation. See: MCT parameter.
Solution:
Check material source. MCT parameter alarm may indicate
a problem with material loading, blending issues or delays in
completing a cycle such as vibration.
ALTERNATE COLOR ALARM
ALARM CODE:24
Alert Alarm: Alternate Liquid Color, Component
Switch.
The Alternate Liquid Color option allows automatic switch over from
Liquid Color component 10 to liquid color component 11 when
component 10 runs out (switch over continues from 11 to 10 and so
on). This alarm is triggered by a switch over of the component
configured to switch over liquid color. For more details see Alternate
Liquid Color under Operating Options and also the LIQ parameter.
Solution: Replace Liquid Color component that has run out.
MIX MOTOR FAILURE ALARM
ALARM CODE:25
Problem: Mix Motor Failure Detected.
When enabled under Specialized Alarms and used with the Mix Motor
Failure Kit (KIT-075T), this alarm will sound when the mix motor fails
to move during intended operation.
Solution:
Check operation of Mix Motor. Check for material jam in
mix chamber, check for mix blade obstructions. Clear mix chamber
and Mix Motor operation using Manual Operations. Check thermal
overload fuse on larger blender (model 900 and higher) or Mix Motor
Fuse on Controller.
TOTALS ALARM
G2F PARAMETER ALARM
ALARM CODE:26
Problem: Totals have not been collected by
communications for previous cycle.
The G2F parameter is used in conjunction with the Get Totals
command. The Get Totals MLAN command can be sent with either a
command code of 16 or 17. If Get Totals used command code 16, an
internal flag in the controller is set indicating the totals have been
collected for this cycle. If Modbus is used for communication, any
registers read between 40014 and 40037 will count as collected
totals. If the Totals Alarm is enabled, the blender will alarm and
continue or alarm and stop running cycles depending on the selection
in setup, because the totals had not been collected for the previous
cycle. At that time the "Get Status" MLAN protocol command and
Modbus register 40012 will return an alarm status of 26.
Solution:
Check communication status to this blender.
USB RECIPE ALARM
ALARM CODE:30
Problem: USB Recipe Command is enabled but
Recipe not found on USB drive.
When enabled, the USB Recipe Command causes the controller to
look for the recipe file located on the USB drive before dispensing the
next cycle. If the USB recipe file is not found on the flash drive, this
alarm will occur.
Solution:
Check for the USB drive, check for the recipe file on the
USB drive.
Summary of Contents for Weigh Scale Blender 4088
Page 6: ...6 EC Declaration of Conformity ...
Page 10: ...10 Blender Parts Key ...
Page 13: ...13 ...
Page 104: ...104 Technical Drawings ...
Page 105: ...105 ...
Page 106: ...106 ...
Page 107: ...107 ...
Page 108: ...108 ...
Page 109: ...109 ...
Page 110: ...110 ...
Page 111: ...111 ...
Page 112: ...112 ...
Page 113: ...113 ...
Page 114: ...114 ...
Page 115: ...115 ...
Page 116: ...116 FCA INSTALLATION DIAGRAM ...
Page 117: ...117 WSB 4088 IO wiring diagram 120V ...
Page 118: ...118 D WSB E0001 Electrical Diagram WSB Export Single Phase ...
Page 119: ...119 D WSB E0002 Electrical Diagram WSB Export 3 Phase ...
Page 120: ...120 D WSB E0003 Electrical Diagram WSB Export 1800 3 Phase ...
Page 121: ...121 D WSB E0004 Electrical Diagram WSB Export Maxibatch ...
Page 123: ...123 D WSB P0001 Pneumatic Diagram WSB with Non Removable Hoppers ...
Page 124: ...124 D WSB P0002 Pneumatic Diagram WSB with Removable Hoppers ...
Page 125: ...125 ...
Page 143: ...143 Flexbus Lite Wiring Diagrams ...
Page 144: ...144 ...
Page 145: ...145 ...
Page 146: ...146 Flexbus Lite Component Map ...