63
detection checks for a gram change in weight (weight gain for valve leak, weight loss
for weigh-bin leak) three times in a row. Then, to minimize false positives, the logic
does the same check again as a verification step. WDD is broken into two fields:
digits 2+3 are the weigh bin leak tolerance in grams. Digits 4+5 are the valve leak
tolerance in grams. Defaults: WSB MB, 100, 200: 02020. WSB 400, 900, 1200,
1800: 04040. WSB 2400, 3000: 08080.
BER - Grams over weight to abort a component dispense.
This parameter prevents over filling the weigh bin.
A component dispense aborts when weight exceeds target by BER value.
Remaining components dispense normally.
1 in the last position (00201), causes USB printout of cycle data when abort occurs.
Typically, no change is required.
If vibration causes false abort, then set a higher value.
Default is 00200 (20 grams or 200 grams model dependent).
Micro Blender (MB), 100, 200 Series - 10ths of grams
400, 900, 1800, 2400, 3000 Series
– grams
ROC 00000
REGRIND OVERCOLOR - ROC, ROV, and RHL help control regrind usage.
ROC indicates the PERCENT of REGRIND that will be treated as natural when
COLOR and ADDITIVE dispenses are calculated. This adds some color or additive
to your regrind.
ROV 00000 REGRIND OVERRIDE -
ROV is for closed loop fully automatic reprocessing of
regrind scrap. This parameter will detect when more regrind is being produced than
consumed, and override the current setting to use a higher amount. This helps
prevent material backing up in your grinder.
RHL 00000
REGRIND LEVELS
– HI/LOW -
RHL has effect only if level sensors are added to
your unit to detect material level in the regrind hopper. These level sensors can alter
regrind percent usage.
MIX 00015
Mix Time (Seconds)
TIME mixer motor runs after weigh bin dumps.
JOG 03030 Mixer operation after MIX time (count/seconds)
After MIX time, JOG will operate mixer 1 turn, every xx seconds for a total count of
xxx times. First 3 digits
000
00 is the total count. Last two digits 000
00
is the interval
in seconds.
MPO 00000 Micro Blender Mix Time
For Micro Blender air driven reciprocating mixer
MPO sets the timing, in tenths of seconds the clockwise and counterclockwise timing
of the mix blade. MPO 00010 is 1 second for each direction.
FCV 00006 Flow Control Valve - Delays opening and closing of the flow control valve
Digit 1 = When Power Off: 0 = CLOSED (default), 1 = OPEN
(must reverse air lines).
Digits 2 and 3 = time delay in seconds before closing.
Digits 4 and 5 = time delay in seconds before opening.
Summary of Contents for Weigh Scale Blender 4088
Page 6: ...6 EC Declaration of Conformity ...
Page 10: ...10 Blender Parts Key ...
Page 13: ...13 ...
Page 104: ...104 Technical Drawings ...
Page 105: ...105 ...
Page 106: ...106 ...
Page 107: ...107 ...
Page 108: ...108 ...
Page 109: ...109 ...
Page 110: ...110 ...
Page 111: ...111 ...
Page 112: ...112 ...
Page 113: ...113 ...
Page 114: ...114 ...
Page 115: ...115 ...
Page 116: ...116 FCA INSTALLATION DIAGRAM ...
Page 117: ...117 WSB 4088 IO wiring diagram 120V ...
Page 118: ...118 D WSB E0001 Electrical Diagram WSB Export Single Phase ...
Page 119: ...119 D WSB E0002 Electrical Diagram WSB Export 3 Phase ...
Page 120: ...120 D WSB E0003 Electrical Diagram WSB Export 1800 3 Phase ...
Page 121: ...121 D WSB E0004 Electrical Diagram WSB Export Maxibatch ...
Page 123: ...123 D WSB P0001 Pneumatic Diagram WSB with Non Removable Hoppers ...
Page 124: ...124 D WSB P0002 Pneumatic Diagram WSB with Removable Hoppers ...
Page 125: ...125 ...
Page 143: ...143 Flexbus Lite Wiring Diagrams ...
Page 144: ...144 ...
Page 145: ...145 ...
Page 146: ...146 Flexbus Lite Component Map ...