M A G U I R E P R O D U C T S , I N C .
10
G R A V I M E T R I C A U G E R F E E D E R
Touchscreen Overview
Home Screen
The Home Screen contains
several fields and buttons:
Title Bar
- Located across the top of the
screen, the title bar displays Model, ID,
current operating mode, date and time,
Ethernet and USB status.
Info
- The
i
(info) button displays
information about the MGF including
firmware and serial number.
Actual Weight
– The actual weight of material currently in the hopper.
Mode
– Displays current configuration. Cycle, Continuous or Extrusion Following mode.
Recipe
– Screen to set, save and load preconfigured MGF settings.
Tag
– Screen to set material tag information. Operator, Recipe and Work Order tags. Used in communications.
Shot Weight or Rate
– Displayed setting based on selected Mode. Metering Rate or Shot Weight. See page 11.
Load
– On/Off button (if enabled) activates the loader. See page 27.
Prime
– Primes and calibrates the MGF - See page 14.
Start / Stop Button
– Main Start / Stop Control Button of the MGF.
Let Down Ratio (LDR)
– Let Down Ratio, Percent. See page 11.
View
– Screen to view, clear or save: MGF ID, date/time, totals, cycles, work order, recipe, operator. See page 33
Injection / Recovery
–Cycle Mode only. Displays the state of the cycle, Injection or Recovery.
Navigation Menu
- Located along the right side of the screen, these buttons allow quick navigation to frequently
used and top-level screens. The middle three buttons are soft buttons that can be changed or removed.
Home Screen
Pressing the Home Screen button from any other screen will return the operator to the main
Home Screen.
Alarm and Event
Alarm and Event Log displays a history of alarms and other events with a date and time
stamps and description.
Live Diagnostics
Live Diagnostics displays a cycle summary of detailed diagnostics information scrollable
back through a history of cycles printable to USB.
Print Center
A menu screen of print related options including Totals, Parameters, Alarm History, Events,
Cycle History, Diagnostics.
Setup
Password protected area to access the MGF settings. See page 18.
View Totals
Injection/Recovery
Navigation Menu
Start / Stop
Let Down Ratio
Shot Weight
or Rate
Prime Auger
Run Loader
Title Bar
Actual Weight
MGF Status
Summary of Contents for GRAVIMETRIC AUGER FEEDER MGF-ST
Page 5: ...M A G U I R E P R O D U C T S I N C 5 G R A V I M E T R I C A U G E R F E E D E R...
Page 37: ...M A G U I R E P R O D U C T S I N C 37 G R A V I M E T R I C A U G E R F E E D E R...
Page 38: ...M A G U I R E P R O D U C T S I N C 38 G R A V I M E T R I C A U G E R F E E D E R...
Page 40: ...M A G U I R E P R O D U C T S I N C 40 G R A V I M E T R I C A U G E R F E E D E R...
Page 41: ...M A G U I R E P R O D U C T S I N C 41 G R A V I M E T R I C A U G E R F E E D E R...
Page 43: ...M A G U I R E P R O D U C T S I N C 43 G R A V I M E T R I C A U G E R F E E D E R...
Page 44: ...M A G U I R E P R O D U C T S I N C 44 G R A V I M E T R I C A U G E R F E E D E R...