Type the new password, then type the password again in the 2nd field to 
confirm.  Valid passwords are numbers 0-9, 1 to 6 characters long.  Press 
the green check 

 when complete. 

 

Set Language, Set Date Format 

Sets the language (if applicable in firmware update) and Sets the Date 
Format to US or European.  Press the green check 

 when complete. 

 

Pump Alarm Setup 

Enables or disables pump Filter Alarm and pump Motor Failure Alarm.  

Filter Alarm

 - On power up, system detects if filter is present.  During 

pump operation system detects a clogged filter.  

Motor Failure Alarm

 - Optional motor failure detection.  See wiring 

diagram on page 22.  
Press the green check 

 when complete.

 

 

TCP/IP Configuration 

Enter the IP address for the Flexbus controller for Modbus TCP 
communications.  MAC address is provided on-screen for DHCP.  See the 
Maguire Modbus Register Mapping document for more information. 

 

Summary of Contents for FLEXBUS

Page 1: ...MAGUIRE PRODUCTS INC FLEXBUS FLEXBUS Lite FLEXBUS FLEXBUS Lite RECEIVER CONTROL SYSTEM INSTRUCTION MANUAL Original Instructions Manual Revision Date January 31 2020 Copyright Maguire Products Inc 2020...

Page 2: ...M A G U I R E P R O D U C T S I N C 2 M A G U I R E FLEXBUS...

Page 3: ...c accepts no responsibility or liability for damage or malfunction of the equipment arising from non observance of these operating instructions To avoid errors and to ensure trouble free operation it...

Page 4: ...__________________ 11 Receiver Configuration ______________________________ 12 Pump Configuration _________________________________ 14 Removing Receivers or Pumps ________________________ 16 Flexbus S...

Page 5: ...m loaders Easy Installation Install a single wire and conveniently located drops to connect the control to all receivers and pumps System Grows with Your Needs Each Flexbus central control allows addi...

Page 6: ...rned on and discovered during the Pump Assignment routine and the Receiver Assignment routine setup processes Once the initial setup has been completed the Flexbus system will retain the setup and ide...

Page 7: ...o enabled Flexbus Lite in the Maguire Weigh Scale Blender Press Display will prompt for a password default 22222 Then press Press System Configuration Display will show the System Configuration catego...

Page 8: ...ssword is 22222 Press to confirm password This enters the Setup screen This screen contains several setup specific options Pumps and Receivers Setup Buttons Pressing PUMPS or RECEIVERS enters Setup fo...

Page 9: ...of the screen This enters the PUMP assignment screen This gray screen contains any previously assigned pumps For first time setup this screen is probably blank and no pumps have been assigned At this...

Page 10: ...S While in the Setup screen you can go straight to setting up Receivers without re entering the password PRESS To enter the Receivers assignment screen See Next Page for Receivers Assignment instructi...

Page 11: ...then to be assigned Your receivers will appear on the screen and be numbered in the order that they were turned on If necessary pressing each receiver icon will allow you to re assign the ID number to...

Page 12: ...reen using the arrow buttons and allows the receiver to be turned OFF or ON The receiver symbol can display the following states Pressing the Receiver symbol toggles receiver OFF or ON This symbol ind...

Page 13: ...e valve will open to purge the convey line Purge time follows Load time Priority Sets the order of importance of the receivers Setting a receiver to level 1 sets to the highest priority while setting...

Page 14: ...e pump navigation arrows at the bottom center of this screen Pump Overview Screen Pump Configuration Screen Pump Navigation Pump Navigation and Status Panel This multi function panel displays messages...

Page 15: ...lt Time Interval is 5 1 400ms IDLE TIME The time in minutes that the pump runs after the last convey request before shutting off BYPASS The time delay in 10ths of seconds 0 50 zero seconds to 5 second...

Page 16: ...st be turned off or communication must be disconnected to remove the device When a device is turned off or communication to the device is disconnected the loader or pump icon will show a red X over it...

Page 17: ...ordinates To complete follow the prompts Press the green check when complete Update Flexbus Touchscreen Firmware Requires a firmware update provided by Maguire Products Inc Copy firmware to USB and in...

Page 18: ...the green check when complete Pump Alarm Setup Enables or disables pump Filter Alarm and pump Motor Failure Alarm Filter Alarm On power up system detects if filter is present During pump operation sys...

Page 19: ...Setup Enters password protected setup screens Receivers Navigation Setup of all Receivers Pumps Navigation Setup of all Pumps Live Status Panel In the Live Status Panel the receivers will display the...

Page 20: ...r s power is off or a disconnected communication wire Receiver is inactive Receiver is alarming Virgin material filling receiver Regrind material filling receiver Regrind Layering Proportional Loading...

Page 21: ...d Alarm Log Each event or alarm will have the date and time the receiver or pump ID number involved in the alarm or log and the reason for the alarm or log Alarms and logs are listed with the most rec...

Page 22: ...M A G U I R E P R O D U C T S I N C 22 M A G U I R E FLEXBUS Flexbus Wiring Diagrams...

Page 23: ...M A G U I R E P R O D U C T S I N C 23 M A G U I R E FLEXBUS...

Page 24: ...M A G U I R E P R O D U C T S I N C 24 M A G U I R E FLEXBUS Flexbus Component Map...

Page 25: ...M A G U I R E P R O D U C T S I N C 25 M A G U I R E FLEXBUS Flexbus Lite Component Map...

Page 26: ...M A G U I R E P R O D U C T S I N C 26 M A G U I R E FLEXBUS...

Page 27: ...M A G U I R E P R O D U C T S I N C 27 M A G U I R E FLEXBUS...

Page 28: ...d and of all other obligations or liabilities on our part and MAGUIRE PRODUCTS neither assumes nor authorizes any other persons to assume for it any other liability in connection with the sale of its...

Page 29: ...459 4300 Fax 610 459 2700 Email info maguire com Web www maguire com Maguire Europe Tame Park Tamworth Staffordshire B775DY UK Tel 44 1827 265 850 Fax 44 1827 265 855 Email info maguire europe com Mag...

Reviews: