Type the new password, then type the password again in the 2nd field to
confirm. Valid passwords are numbers 0-9, 1 to 6 characters long. Press
the green check
when complete.
Set Language, Set Date Format
Sets the language (if applicable in firmware update) and Sets the Date
Format to US or European. Press the green check
when complete.
Pump Alarm Setup
Enables or disables pump Filter Alarm and pump Motor Failure Alarm.
Filter Alarm
- On power up, system detects if filter is present. During
pump operation system detects a clogged filter.
Motor Failure Alarm
- Optional motor failure detection. See wiring
diagram on page 22.
Press the green check
when complete.
TCP/IP Configuration
Enter the IP address for the Flexbus controller for Modbus TCP
communications. MAC address is provided on-screen for DHCP. See the
Maguire Modbus Register Mapping document for more information.