Section 2. Communications
63
Save Custom Keymap Command (KB)
Command number:
0x05
Description:
This command is used to save the active key map as the custom key map
in non volatile memory. The active key map is determined by the active
key map property. Once a key map item is modified, the changes take
affect immediately. However, the changes will be lost if the reader is reset
or power cycled. To make the changes permanent, the save custom key
map command must be issued. To use the new custom key map after a
reset or power cycle, the active key map property must be set to custom.
Data structure:
Request Data: None
Response Data: None
Result codes:
0x00 Success
0x07 Incorrect MAC – Command not authorized
Example
Save Custom Keymap
Request (Hex):
Cmd Num
Data Len
Data
05
00
Example
Save Custom Keymap
Response (Hex):
Result Code Data Len
Data
00
00
DUKPT Operation
Since key loading is proprietary and performed at MagTek, there are no user commands to
support key injection.
Get DUKPT KSN and Counter Command
Command number:
0x09
Description:
This command is used to report the Key Serial Number and Encryption
Counter.
Data structure: No data is sent with this command.
Response Data:
Offset
Field Name
Description
0
Current Key
Serial Number
This eighty-bit field includes the Initial Key Serial
Number in the leftmost 59 bits and a value for the
Encryption Counter in the rightmost 21 bits.
Result codes:
0x00 Success
0x02 Bad Parameter – The Request Data is not the correct length. The
request command contains no data, so the Data Length must be 0.