MagneSafe V5
36
Example Set
Track Data Transmission
Delay
property Response (Hex):
Result Code Data Len
Data
00
00
Example Get
Track Data Transmission
Delay
property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
0D
Example Get
Track Data Transmission
Delay
property Response (Hex):
Result Code Data Len
Prp Value
00
02
02 58
Stay Powered After Swipe Property (BulleT, Flash, Wireless USB)
Property ID:
0x0E
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x00 (Don’t Stay Powered)
Description:
This property controls whether the wireless reader stays powered after a good
swipe. If the property value is 0x00 (the default), the reader powers down
after a good swipe.
If the property value is 0x01, the reader stays powered after a good swipe. In
this case, the reader may be powered down by pressing and holding the User
Switch or it will go off after the activity timeout.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.
RF Address Property (BulleT and Wireless USB Reader)
Property ID:
0x0F
Property Type:
Binary
Length:
4 bytes
Get Property:
Yes
Set Property:
Yes
Default Value:
0x12345678
Description:
The value is a 4-byte number that represents the wireless reader’s and
dongle’s RF address. The RF address is used to pair a wireless reader to a
dongle. All reader/dongle pairs should have a different RF address from all
other reader/dongle pairs. This unique address is what allows more than one
pair to be in range of another pair without having RF commications conflict
with each other.