![Magtek MagneSafe V5 Reference Manual Download Page 38](http://html1.mh-extra.com/html/magtek/magnesafe-v5/magnesafe-v5_reference-manual_3690792038.webp)
MagneSafe V5
30
Example Get
MagneSafe Version Number
property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
04
Example Get
MagneSafe Version Number
property Response (Hex):
Result Code Data Len
Prp Value
00
03
56 30 35
Track ID Enable Property
Property ID:
0x05
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x95
Description:
This property is defined as follows:
id
0
T
3
T
3
T
2
T
2
T
1
T
1
Id
0 – Decodes standard ISO/ABA cards only
1 – Decodes AAMVA and 7-bit cards also
If this flag is set to 0, only tracks that conform to the ISO format allowed for that
track will be decoded. If the track cannot be decoded by the ISO method it will
be considered to be in error.
T
#
00 – Track Disabled
01 – Track Enabled
10 – Track Enabled/Required (Error if blank)
This property is stored in non-volatile memory, so it will persist when the unit is
power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect. This
reader must be unplugged for at least 30 seconds to properly power cycle it.
Example Set
Track ID Enable
property Request (Hex):
Cmd Num
Data Len
Prp ID
Prp Value
01
02
05
95
Example Set
Track ID Enable
property Response (Hex):
Result Code Data Len
Data
00
00
Example Get
Track ID Enable
property Request (Hex):
Cmd Num
Data Len
Prp ID
00
01
05