Troubleshooting
Problem
Possible cause
Solution
Five digits flash simultaneously, once
per second.
Battery voltage lower than 1.45V.
Replace the battery.
Display doesn’t change when the slider
is moved.
Caliper malfunction.
Reset caliper by removing and replacing
battery. Normal function should resume
after 30 seconds.
Less accurate than specified but within
+- 0.1mm.
Dirt in sensor.
Remove slide cover and assembly.
Clean sensor with compressed air.
No display on LCD.
1. Battery in poor contact.
2. Battery voltage under 1.4V.
1. Remove battery cover and adjust
the battery.
2. Replace battery.
Technical data
Component
Specification
Measuring range
0-75mm / 0-3”, 0-100mm / 0-4” 0-150mm / 0-6”, 0-200mm / 0-8” 0-300mm / 0-12”
Resolution
+-0.01mm / 0.0005”
Accuracy
+-0.02mm / 0.001” (<100mm)
+-0.03mm / 0.001” (>100-200mm) +-0.04mm / 0.0015” (>200-300mm)
Repeatability
+-0.01mm / 0.005”
Max. measuring speed
1.5m / sec
Measuring system
Linear capacitive measuring system
Display
LCD display
Power:
1x1.5V button cell. (capacity: 165mAh)
Working temperature
5°C - 40°C / 41 - 104°F