Use and installation manual for a MAGNUM sauna stove
16.06.2015 13
Starsauna Oy
Technical support:
Pistotie 4
15860 Hollola, Finland
Section III.2
Installing the thermostat sensor
Heat sensor Connection of the LIYY wire
Connecting the sensor wire from the left LIYY CABLE (gray):
To
connector
Brown
White
Green
Yellow
To circuit
card
1
2
3
4
Connection of the sensor wire, from the left SILICONE
CABLE (light brown, right on the picture):
To
connector
Blue
White
Red
Yellow
To circuit
card
1
2
3
4
All Magnum sauna stoves bought from 1 October 2015 onwards have been equipped
with the new silicone cable.
Connect the connector to the circuit card’s connector and press it carefully all the
way down.
When installing the thermostat sensor on the wall, the distance from the roof to the
upper edge of the sensor should be 100 mm. The sensor must be located 500-1000
mm from the upper edge of the sauna stove.
Furthermore, the sensor must be located at least 1000 mm from a non-directed incoming
air valve or 500 mm from an incoming air valve which is located away from the device.
See the image at page 16.
Install the thermostat cable behind the panel in the air
vent. If this is not possible, use an installation baseboard.
Make sure that the incoming air does not disturb the heat
sensor.
Do NOT cut the wire
from the thermostat’s side. The
thermostat sensor does not function if the wires are
continued/reconnected. If the wire needs to be shortened,
shorten it from the connector's side. In other cases,
contact the technical support.