Use and installation manual for a MAGNUM sauna stove
16.06.2015 7
Starsauna Oy
Technical support:
Pistotie 4
15860 Hollola, Finland
II.
Using the sauna stove
Section II.1
Adjustable settings
Section II.2
Target temperature
The sauna's target temperature may be adjusted in steps of one Celsius. The
minimum temperature is 40 degrees and the maximum temperature is 110 degrees.
This setting is saved.
The target temperature may be adjusted in two different ways.
1.
The Menu button shows the target temperature on the screen.
You may use the +/
˄
and –/
˅
buttons to change the value. If you do
not press any buttons, the controller will stop displaying the target
temperature menu automatically in approximately 10 seconds. You
may also leave the menu by pressing the Menu button repeatedly.
2.
When the sauna temperature is on the display, pressing the (+/
˄
) or
(–/
˅
) button causes the controller to move directly to setting the
target temperature. Leaving this menu is done as in section 1.
Section II.3
Heating time
You may set the sauna stove's heating time to be between 1 h and 6 h. The
adjustment takes place in steps of 0.5 h.
This value needs to be set when the device is turned off.
You may move to this setting from the default mode by pressing the Menu button
twice.
It is possible to reduce the time the stove is on when the sauna is heating.
You may increase or decrease the time of the sauna session by pressing the (+/
˄
) or
(–/
˅
) button when the remaining time is on the display. In this case, the adjustment
step is 15 minutes. This setting is not saved to the memory. You can go back to the
default mode by pressing the Menu button twice.
Parameter
Adjustment step
Adjustment
step
Default
value
Note!
Target
temperature
40…110 °C
1 °C
60 °C
Heating time
1 h…6 h
30
min
1 h
see section 2.3
Timer time
0.5 h...24 h
30
min
0 h
(not in use)