Operation
Page 64
©
2017 Sensata Technologies
PT Max Charge Time
appears on LCD. PWR (green)
LED is on solid and CHG (green) LED blinks.
FAULT
PWR
CHG
INV
PT Max Charge Time
Settings/Info...
• PT Max Charge Time
– This display indicates the PT Max Charge Time safety feature was
enabled because the charge time was longer than the PT
Max Charge: Time
setting.
Info:
The
PT
Max Charge Time safety feature uses the time accumulated under the
METER: 03A Charge Time
display to determine the total charge time.
Info:
The PT
Max Charge: Time
display can be reset by either reconnecting AC to
the inverter, or by pressing the CTRL button and enabling the “
Start Bulk
” or “
Start
EQ
”option under the
CTRL: 05A PT Chg Ctrl
menu—which initiates another charge cycle
(Bulk, EQ, or Constant Current).
Info:
The timer for the PT
Max Charge: Time
menu runs when the battery voltage is
greater than 0.2 volts above the
fl
oat voltage setting.
Figure 5-26, PT Max Charge Time
•
Inv Max Charge Time
– This display indicates the Max Charge Time safety feature was
enabled because the Absorption charge was longer than the
Max Charge: Time
setting.
If
SETUP/03C Battery Type: CC/CV
is selected: The charger was forced to transition to the Silent
charge stage because the charger had been in Constant Current and Constant Voltage charge
modes longer than the
Max Charge: Time
setting [under the
Chg Done Time
(or
Amps
) selection].
If
SETUP/03C Battery Type: CC/CV
is not selected: The charger was forced to transition to the
fi
nal charge stage (Float, Silent, or Full Charge) as set under the SETUP button’s
03F Final Charge
Stage
. This safety feature occurred because the charger had been in Bulk, Absorption, or EQ
charge modes longer than the
Max Charge: Time
setting.
Info:
The
Inv
Max Charge Time safety feature uses the time accumulated under the
METER: 03A Charge Time
display to determine the total charge time.
Info:
The Inv
Max Charge: Time
display can be reset by either reconnecting AC to the
inverter, or by pressing the CTRL button and enabling the “
Start Bulk
” option under
the
CTRL: 02 Charger Control
menu—which initiates another charge cycle (Bulk, EQ, or
Constant Current).
Info:
The timer for the Inv
Max Charge: Time
menu runs when the battery voltage is
greater than 0.2 volts above the
fl
oat voltage setting.
FAULT
PWR
CHG
INV
Inv Max Charge Time
Settings/Info...
Inv Max Charge Time
appears on LCD. PWR (green)
LED is on solid and CHG (green) LED is blinking.
Figure 5-25, Inv Max Charge Time Mode
Summary of Contents for ME-ARTR
Page 1: ...ME ARTR Advanced Router Owner s Manual Version 4 0 ...
Page 181: ...NOTES ...