2020 Sensata Technologies
Page 25
Installation
240
VAC only
in standby
Main Panel
(Utility/Generator Input)
MSH3012RV
Series Inverter
AC Terminal Block
(AC input and output wiring)
DUAL IN / DUAL OUT wiring
Sub-Panel and Outlets
(Inverter Loads)
120
VAC
120
VAC
AC GROUNDS
(to/from
both panels)
ON
OFF
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
50
..
Maximum
..
50-amp breaker
(double pole)
required to
inverter AC input
50
In mobile installations:
neutral is typically not
connected to ground in main panel.
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OFF
AC NEUT IN
(from main panel)
AC HOT 1 IN
(from main panel)
AC HOT 2 IN
(from main panel)
AC HOT 1 OUT
(to sub-panel)
AC HOT 2 OUT
(to sub-panel)
AC NEUT OUT
(to sub-panel)
Figure 2-11, AC Wiring for Dual In – Dual Out Confi gurations