Page 29
Installation
2.7 Inverter Warning Label
A warning label as shown in Figure 2-15 is provided to inform all personnel that an inverter is
installed in your electrical system. Af
fi
x this label in a clearly visible location at the electrical panel
that is being powered by the inverter. This is because it might be falsely assumed that the panel
is no longer “hot” after the AC power has been shut off, when power may actually still be available
due to the inverter automatically powering the panel.
Figure 2-15, Warning Label
2.8 RV-C Communication Connection Port
The MSH3012RV inverter/charger has a RV-C connection port (Figure 1-1, Item 5). This connection
port is used to communicate with RV-C compliant devices that are connected to the RV-C network
bus/backbone in the RV (Figures 2-16 and 2-17). Use the information shown in Figure 2-18 to connect
the inverters 4-pin RV-C connector to the plug and cable from the RV-C network bus in the RV.
Info:
Power needs to be provided to the RV-C connector from the RV-C network bus.
Note:
The RV-C plug and cable are NOT supplied.
Magnum MSH3012RV
Network Bus/Backbone In RV
RV-C
compliant
device
RV-C
compliant
device
T
T
Te
rm
in
a
to
r
Te
rm
in
a
to
r
Phone
splitter
ME-AGS-N
ME-BMK
Figure 2-16, RV-C Connections (Single Inverter with Accessories)
WARNING
ELECTRICAL SHOCK HAZARD
PN: 62-0002 Rev B
This electrical system is equipped with an Automatic Generator
Starting (AGS) device and/or an inverter. Disconnect all AC and
DC power to the AGS and/or inverter before performing any
service to the electrical system. Failure to do so can result in
shock causing serious injury or death.