Page 38
©
2020 Sensata Technologies
Operation
Figure 3-8, MSH3012RV Current Flow – Load Support AAC
MSH Inverter
AC Loads
(Large)
+30A
DC Current
(Battery)
-10A
AC Current
(Grid/Gen)
-20A
Load Support AAC
– If AC loads are added that are above the capability of the grid/generator,
the MSH3012RV converts current from the battery and combines it with the current from the grid/
generator to power the additional AC loads.
Figure 3-9, MSH3012RV Current Flow – Load Support VDC
MSH Inverter
AC Loads
(Large)
+30A
DC Current
(Battery)
-20A
AC Current
(Grid/Gen)
-10A
Load Support VDC
– If the battery is being charged externally (i.e., alternator, solar, etc.), the
MSH3012RV reduces the current from the grid/generator, and then converts any excess current
from the battery to power the AC loads and to keep the battery from rising.