2020 Sensata Technologies
Page 51
Appendix A – Specifi cations
Figure A-3, Temperature to Continuous Charger Output Current
80
100
110
120
90
25
35
30
40
45
50
55
60
Temperature (
°
C)
C
o
nt
in
u
o
us
C
h
a
rg
e
r
Cu
rr
en
t
(A
D
C
)
130
A-2.3
Temperature and Charger Output
The following curve (Figure A-3) is plotted to show the MSH3012RV charger’s continuous output
current as the ambient temperature rises.
A-4 Optional Equipment and Accessories
The following Sensata Technologies components are available for use with the MSH3012RV.
Standard Remote Control
The ME-RC remote control panel uses an LCD screen and at-a-glance LEDs display for complete
inverter/charger status. Soft keys provide simple access to menus, and a rotary encoder knob
allows you to scroll through/select a wide range of settings.
Advanced Remote Control
The ME-ARC remote control panel uses an LCD screen and at-a-glance LEDs to provide operating
information and allow advanced features to be con
fi
gured (requires an inverter with advanced
con
fi
gurable features).
Auto Generator Start Controller
The ME-AGS-N Automatic Generator Start controller (Network version) is designed to automatically
start a wide range of generators based on low battery condition or high temperature. Adjustable
settings when using the ME-ARC include starting the generator based on battery voltage, time of
day, battery State of Charge, or high temperature.
Battery Monitor Kit
The ME-BMK Battery Monitor Kit is a single battery bank amp-hour meter that monitors the condition
of the battery, provides information to let you know how much energy you have available, and
lets you plan your electrical usage to ensure the battery is not being over-discharged. Order Part
Number: ME-BMK-N to receive the battery monitor without the 500A/50mv DC shunt.
Table A-1, AC Output Fault Current - Inverter Mode
Test Condition
Max Output Fault Current
Peak Duration
3-Cycle RMS Value
Output Short Circuit
240.5 Amps Pk-Pk
1.45 mSec
76.08 Amps
A-3 Inverter AC Fault Current
The following table is provided in accordance with CSA C22. No. 107.1-2017, Clause 10.4.5.