52
58-610 Model R82 Radar Transmitter
3.4
Agency Approvals
United States
R82-52XA-0XX
Intrinsically Safe
Class
I
, Div. 1; Groups A, B, C, & D
T4 @80°C; Type 4X, IP66/67
¿
Entity
R82-51XA-0XX
Non-Incendive
¡
Class
I
, Div. 2; Groups A, B, C, & D
Type 4X, IP66/67
¿
Canada
R82-52XA-0XX
Intrinsically Safe
Class
I
, Div. 1; Groups A, B, C, & D
T4 @80°C; Type 4X, IP66/67
¿
Entity
R82-51XA-0XX
Non-Incendive
¡
Class
I
, Div. 2; Groups A, B, C, & D
T4 @80°C; Type 4X, IP66/67
¿
ATEX/IEC
R82-5BXA-0XX
Intrinsically Safe
¬√
II
1G Ex ia
II
C T4 @70°C
EN60079-0: 2006/IEC 60079-0: 2007
Ambient Temp: -40 to +70 °C
EN60079-11: 2007/IEC 60079-11: 2006
Ex ia
II
C T4 Ga
EN60079-26: 2007 standards applied/
IEC 60079-26: 2006
BRAZIL
R82-5BXA-0XX
Intrinsically Safe
¬√
BR-Ex ia
II
C T4, IP66/IP67
¿
ABNT NBR IEC 60079-0: 2006
ABNT NBR IEC 60079-0: 2006
ABNT NBR IEC 60079-11: 2009
Ambient Temp: -40 to +70 °C
ABNT NBR IEC 60529: 2005
AEX-12645-X
INMETRO/TÜV
AGENCY
MODEL
PROTECTION METHOD
AREA CLASSIFICATION
These units have been tested to ETSI EN 302 372-1
and ETSI EN 301 489-1 and are in compliance with the
RTTE Directive 1999/5/EC. In addition these units were
tested to EN 61326 and are in compliance with the
EMC Directive 2004/106/EC.
COMMUNICATIONS APPROVALS
IEC/ATEX Entity Parameters
Region
Agency
Frequency
US
FCC
26 GHz
Canada
IC
Europe
RTTE
Ui
28.4 VDC
28 VDC
li
94 mA
120 mA
Pi
0.67 w
0.84 w
Ci
5.5 nF
Li
370
m
H
Model R82
SIL
1 as 1oo1
Instrument Type
B
SFF
89.1%
PFDavg
3.34E-04
FITS
Annual
Fail Dangerous Undetected
68
5.96E-04
Fail Dangerous Detected
388
3.40E-03
Safe
169
1.48E-03
¿
Type 4X rating applies to aluminum housing only;
IP67 rating applies to Lexan housing only.
¡
For Division 2 the measured media inside the vessel must be non-flam-
mable only. The transmitter must be connected to an inherently limited
Class 2 power source (as defined in the NEC Table 11), or as a low
energy Class 2 power source (as defined in the CEC Section 16).
Special conditions for safe use (ATEX/IEC Ex i)
¬
Materials marked as Category 1 equipment and mounted in hazardous
areas requiring this Category shall be installed in such a way that, even
in the event of rare incidents, the aluminum enclosure cannot be an
ignition source due to impact or friction.
√
The transmitter shall be installed so that electrostatic discharges on
plastic parts are prevented.
SIL
Radar level device installed in closed
plastic tanks, metallic tanks or reinforced
concrete tanks.