background image

Product Transition Guide

G+ Mini Rev:

G+ Mini Transition Guide  September 2008
Page 8 of 24
Magnetek, Inc.

Note:

 The current input for terminal A1 is not available on the G+ Mini. Use terminal A2 for current input.

Network Communications Terminals

"–" indicates that an equivalent terminal on the other unit does not exist.

FS

+V

Analog input power supply

+12 V (max. current 20 mA)

+10.5 V (max. current 20 mA)

FR

A1

Analog input 1
Voltage or current (not available on G+ Mini - 
see Note) input (frequency reference) 

0~+10 VDC (20 kW),

0 or 4~20 mA (250 kW) 

0~+10 VDC (20 kW) 

A2

Analog input 2 
(frequency reference)

DC:0~+10 V (20 k

)

0 or 4~20 mA (250 k

(initial setting: 4-20 mA) 

FC

AC

Analog input common

0 V

HC

Hard wire baseblock common

+24 V (max. current 10 mA)

H1

Hard wire baseblock input 
(EN954-1, category 3, Stop category 0) 

Open: Stop

Closed: Operation

MA

Multi-Function Digital Output 
(N.O. Contact) (Fault)

Max. AC load:

250 VDC, 1 A max.

30 VDC, 1 A max. 

Max. load:

AC:250 V, 10 mA~1 A

DC:30 V, 10 mA~1 A

MB

Multi-Function Digital Output 
(N.O. Contact) (Fault)

MC

Multi-Function Digital Output
 (common)

P1

Open collector output 1 
(during run)

Photoc48 VDC, 50 mA or less Output

P2

Open collector output 2 
(speed agree)

PC

Open collector output common

MP

Pulse output 
(output frequency)

Max. 32 kHz

AM

Analog output

DC:0~+10 V, 2 mA max.

Resolution: 8 bit

DC:0~+10 V, 2 mA max.

Resolution: 1/1000 

AC

Analog output GND

Serial 

Communication

Terminals

Function

Signal Level

P3 

Series 

2

G+ 

Mini

P3 Series 2

G+ Mini

R+

R+

R

RS-485/422 MEMOBUS

Protocol

Max. 19.2 kbps

RS-485/422 MEMOBUS

Protocol

Max. 115.2 kbps

R-

R-

Receive -

S+

S+

Tr

S-

S-

Transmit -

GND

IG

Shield connection, GND

0V

0V

Control 

Terminals

Function

Signal Level

P3 

Series 

2

G+ 

Mini

P3 Series 2

G+ Mini

Summary of Contents for P3 Series

Page 1: ...G Mini Transition Guide Product Transition Guide P3 Series 2 to G Mini Distributed by Ergonomic Partners Sales ErgonomicPartners com 314 884 8884 www ErgonomicPartners com...

Page 2: ...Product Transition Guide G Mini Rev G Mini Transition Guide September 2008 Page 2 of 24 Magnetek Inc Page Intentionally Left Blank...

Page 3: ...ze Electric Wire Differences 9 Control Terminal Sizes and Wire Sizes 11 1 5 Dimensions Installation Space and Substitution Material 12 P3 Series 2 Dimensions Drive Ratings 12 G Mini Dimensions Drive R...

Page 4: ...ries 2 remote operator to the G Mini as they are incompatible The digital operator for the G Mini can not be mounted remotely Main and Control Terminals Wire Length In the replacement drive the main a...

Page 5: ...ng wiring is long enough to reach the new terminal location Is a braking unit installed Check if a braking unit is used in the current installation Inspect the braking unit for physical damage or wear...

Page 6: ...S2 2003 P3S2 1 6 3 0 1 4 1 2 2001 G M 2003 G M 1 6 3 0 1 4 1 2 2005 P3S2 2008 P3S2 5 0 8 0 3 4 1 2 2005 G M 2008 G M 5 0 8 0 3 4 1 2 2011 P3S2 2017 P3S2 11 0 17 5 3 5 2011 G M 2017 G M 11 0 17 5 3 5 2...

Page 7: ...tput V T2 V T2 W T3 W T3 B1 B1 Braking resistor or external braking unit connection B2 B2 Braking resistor connection 1 1 DC Choke connection DC power supply input 2 2 DC Choke connection DC power sup...

Page 8: ...put EN954 1 category 3 Stop category 0 Open Stop Closed Operation MA Multi Function Digital Output N O Contact Fault Max AC load 250 VDC 1 A max 30 VDC 1 A max Max load AC 250 V 10 mA 1 A DC 30 V 10 m...

Page 9: ...1 2 1 5 14 10 2 0 5 5 14 2 M4 10 6 13 3 1 2 1 5 14 10 2 0 5 5 14 2 12 3 5 14 10 2 0 5 5 12 3 5 2011 2001 R L1 S L2 T L3 U T1 V T2 W T3 1 2 B1 B2 M4 10 6 13 3 1 2 1 5 14 10 2 0 5 5 12 3 5 M4 10 6 13 3...

Page 10: ...L3 U T1 V T2 W T3 1 2 M8 9 11 79 7 11 0 8 38 8 2 38 2 B1 B2 M5 2 2 5 17 7 22 1 8 14 8 6 14 6 Drive Type Terminal Symbol P3 Series 2 G Mini P3S2 G Mini Screw Size Tightening Torque lb in N m Applicabl...

Page 11: ...0 5 5 14 2 4008 4009 R L1 S L2 T L3 U T1 V T2 W T3 1 2 B1 B2 M4 10 6 13 3 1 2 1 5 14 10 2 0 5 5 14 2 M4 10 6 13 3 1 2 1 5 14 10 2 0 5 5 14 2 12 3 5 12 3 5 4014 4014 M4 12 4 1 4 12 10 3 5 5 5 10 5 5 M5...

Page 12: ...ue in lbs N m Applicable Wire Size AWG mm2 Recommended Wire Size AWG mm2 Screw Size Tighten Torque in lbs N m Applicable Wire Size AWG mm2 Recommended Wire Size AWG mm2 MA MB MC M3 4 4 5 3 0 5 0 6 Str...

Page 13: ...0 2 0 4 25 5 04 5 16 3 78 4 65 M4 3 53 72 8 2011 P3S2 11 0 3 0 4 25 5 04 5 51 3 78 4 65 M4 3 53 94 8 2017 P3S2 17 5 5 0 5 51 5 04 5 63 5 04 4 65 M4 5 30 149 1 2025 P3S2 25 0 7 5 7 09 10 24 6 70 6 46 9...

Page 14: ...25 0 7 5 5 51 10 00 5 51 4 80 9 76 M5 8 4 248 5 2033 G M 33 0 10 5 51 10 00 5 51 4 80 9 76 M5 8 4 282 6 2047 G M 47 0 15 7 09 11 42 6 42 6 30 11 18 M5 12 1 389 7 2060 G M 60 0 20 8 66 13 78 7 36 7 56...

Page 15: ...G Mini Transition Guide September 2008 Page 15 of 24 Magnetek Inc Product Transition Guide G Mini Rev IMPULSE P3 Series 2 Wiring Diagram...

Page 16: ...Product Transition Guide G Mini Rev G Mini Transition Guide September 2008 Page 16 of 24 Magnetek Inc IMPULSE G Mini Wiring Diagram...

Page 17: ...01 03 1 Speed Reference Selection A01 04 1 n000 0 4 A01 04 0 4 n000 5 n000 6 n000 7 n000 8 n000 9 A01 04 0 A01 04 1 A01 04 2 A01 04 3 A01 04 4 Initialize A01 05 0 n000 0A A01 05 2220 n000 20 A01 05 99...

Page 18: ...3 01 1 H04 01C 102 n016 xx0x n016 xx1x H04 01 102 H04 01 103 D09 01 D09 02 D09 03 D09 04 0 50B 0 50B 0 50B 0 20 n016 00xx n016 10xx n016 01xx n016 11xx D09 01 4 0 00 D09 01 4 0 20 D09 01 4 0 50 D09 01...

Page 19: ...3 H01 03 H01 05 4 Terminal S4 function selection n033 1 H01 04B 1 n032 34 4 H01 03 H01 05 5 n032 34 5 H01 03 H01 05 13 n032 34 6 H01 03 H01 05 3F n032 34 7 H01 03 H01 05 1 n032 34 8 H01 03 H01 05 32...

Page 20: ...n051 0 10 H03 13 0 03 Terminal S6 function selection n052 0F H01 06 0F P3 Series 2 G Mini n032 34 0 H01 03 H01 05 0 n032 34 1 H01 03 H01 05 1 n032 34 2 H01 03 H01 05 2 n032 34 3 H01 03 H01 05 4 n032...

Page 21: ...05 2005 28 4 16 7 45 1 22 2 14 5 36 7 1 5 2008 2008 53 7 19 1 72 8 41 5 20 4 61 9 2 2 2011 2011 60 4 34 4 94 8 55 2 26 1 81 3 3 7 2017 2017 96 7 52 4 149 1 85 6 37 1 122 7 5 5 2025 2025 170 4 79 4 249...

Page 22: ...rical 30 000 A RMS Symmetrical Control Section Digital Operator Display LED 4x 7 seg LCD option LED 5x 7 seg Digital Operator Number of Keys 6 8 Copy Function Built in Built in USB copy unit option Mi...

Page 23: ...Yes Overtemperature OH Auto Speed Reduction on OH Cooling Fan Bottom mount Top mount Drive Enable Run Permissive None Meets EN954 1 Cat 3 RS485 Comms Comm Speed 19 2kbps 115 2kbps Key Features Parame...

Page 24: ...Mini Product Transition Guide Magnetek Inc N49 W13650 Campbell Drive Menomonee Falls WI 53051 Document Number PL V1000 01 September 2008 Magnetek Inc Distributed by Ergonomic Partners Sales ErgonomicP...