G+ Mini Transition Guide September 2008
Page 21 of 24
Magnetek, Inc.
Product Transition Guide
G+ Mini Rev:
1.7 Appendix
P3 Series 2 and G+ Mini Differences in Watts Loss - Class D Operation
Voltage
Class
Maximum
Motor
Power
kW
P3 Series 2
Type
G+ Mini
Type
P3 Series 2 @ 2.5 KHz
G+ Mini @ 2.0 KHz
Heatsink
Loss (W)
Interior
Unit Loss
(W)
Total Loss
(W)
Heatsink
Loss (W)
Interior
Unit Loss
(W)
Total Loss
(W)
3 Phase
200V
0.2
2001
2001
7.7
10.3
18.0
6.3
8.4
14.7
0.4
2003
2003
15.8
12.3
28.1
13.2
10.8
24.0
0.75
2005
2005
28.4
16.7
45.1
22.2
14.5
36.7
1.5
2008
2008
53.7
19.1
72.8
41.5
20.4
61.9
2.2
2011
2011
60.4
34.4
94.8
55.2
26.1
81.3
3.7
2017
2017
96.7
52.4
149.1
85.6
37.1
122.7
5.5
2025
2025
170.4
79.4
249.8
184.5
64.0
248.5
7.5
2033
2033
219.2
98.9
318.1
206.6
76.0
282.6
-
-
2047
-
-
-
283.4
106.3
389.7
-
-
2060
-
-
-
393.2
143.6
536.8
3 Phase
400V
0.2
4001
4001
9.4
13.7
23.1
10.0
9.1
19.1
0.4
4002
4002
15.1
15.0
30.1
15.6
11.5
27.1
0.75
4003
4003
30.3
24.6
54.9
24.8
13.5
38.3
1.5
4004
4004
45.8
29.9
75.7
39.1
18.3
57.4
3.7
4008
4009
73.4
44.5
117.9
65.9
31.2
97.1
5.5
4014
4014
168.8
87.7
256.5
119.0
54.4
173.4
7.5
4018
4018
209.6
99.3
308.9
151.2
68.2
219.4
-
-
4024
-
-
-
191.3
92.5
283.8
-
-
4031
-
-
-
232.9
111.4
344.3