Product Transition Guide
G+ Mini Rev:
G+ Mini Transition Guide September 2008
Page 12 of 24
Magnetek, Inc.
Control Terminal Sizes and Wire Sizes
Terminal Comparisons
Note:
Refer to G+ Mini Basic Instruction Manual (P/N 144-25084) for warnings, cautions and additional notes.
Terminals
(New/Changed
in G+ Mini)
P3 Series 2
G+ Mini
Screw
Size
Tighten.
Torque
in-lbs
(N•m)
Applicable
Wire Size
AWG
(mm
2
)
Recommended
Wire Size
AWG
(mm
2
)
Screw
Size
Tighten.
Torque
in-lbs
(N•m)
Applicable
Wire Size
AWG
(mm
2
)
Recommended
Wire Size
AWG
(mm
2
)
MA, MB,
MC
M3
4.4~5.3
(0.5~0.6)
Stranded
20~16
(0.5~1.25)
Solid
20~16
(0.5~1.25)
18
(0.75)
M3
4.4~5.3
(0.5~0.6)
Stranded
24~16
(0.25~1.25)
Solid
24~16
(0.25~1.25)
18
(0.75)
S1-S7, P1, P2,
SC, PC, R+,
R-, S+, S-, FS
(V+) FR (A1),
(A2), FC (AC),
AM, AC, RP
(MP), (HC),
(H1)
M2
1.9~2.2
(0.22~0.2
5)
Stranded
20~18
(0.5~0.75)
Solid
20~16
(0.5~1.25)
18
(0.75)
M2
1.9~2.2
(0.22~0.25)
Stranded
24~18
(0.25~0.75)
Solid
24~16
(0.25~1.25)
18
(0.75)