![background image](http://html1.mh-extra.com/html/magnetek/impulse-t-2006-t/impulse-t-2006-t_instruction-manual_3573800079.webp)
IMPULSE•T Instruction Manual – October 2015
A-3
IMPULSE•T Parameter Listing
Parameter
Parameter Name
Default
Range
Units
Reference
Page
A1-01
Parameter Access Level
0000: Operator Only
0002: Advanced
0000
0000, 0002
--
4-10
A1-03
Select Motion
00: Traverse
00
00
--
4-10
A1-04
Speed Reference
00: 2 Speed Multi-Step
01: 3 Speed Multi-Step
02: 5 Speed Multi-Step
03: 2 Step Infinitely Variable
04: Analog - Uni-Polar
01
00–05
--
4-11
A1-05
Initialize
0000: No Initialize
2220: Initialize drive to factory default
settings
0000
0000, 2220
--
4-11
B1-01
Frequency Reference 1
6.00
0.00–E1-04
Hz
5-3
B1-02
Frequency Reference 2
30.00
0.00–E1-04
Hz
5-3
B1-03
Frequency Reference 3
60.00
0.00–E1-04
Hz
5-3
B1-04
Frequency Reference 4
0.00
0.00–E1-04
Hz
5-3
B1-05
Frequency Reference 5
0.00
0.00–E1-04
Hz
5-3
B1-06
Frequency Reference 6
0.00
0.00–E1-04
Hz
5-3
B1-07
Frequency Reference 7
0.00
0.00–E1-04
Hz
5-3
B1-08
Frequency Reference 8
0.00
0.00–E1-04
Hz
5-3
B2-01
Frequency Reference Upper Limit
100.0
0.0–110.0
%
5-4
B2-02
Frequency Reference Lower Limit
0.0
0.0–110.0
%
5-4
B3-01
Reference Source
00: Digital Operator
01: Terminals
00
00, 01
--
5-5
B3-02
Run Source
00: Digital Operator
01: Terminals
01
00, 01
--
5-5
B3-03
Stop Method
00: Decel to Stop
00
00
--
5-5
B3-04
Reverse Oper
00: Normal Rotation
01: Exchange Phases
00
00, 01
--
5-7
B5-01
Accel Time
5.0
0.0–25.5
sec
5-7
B5-02
Decel Time
5.0
0.0–25.5
sec
5-7
D1-02
DC Injection Current
50
0–75
%
5-8
D1-03
DC Injection Time @ Start
0.00
0.00–10.00
sec
5-8
D1-04
DC Injection Time @ Stop
0.50
0.00–10.00
sec
5-8
D9-01
S-Curve Accel @ Start
1.50
0.00–10.00
sec
5-9
D9-02
S-Curve Accel @ End
1.50
0.00–10.00
sec
5-9
D9-03
S-Curve Decel @ Start
1.50
0.00–10.00
sec
5-9
D9-04
S-Curve Decel @ End
0.20
0.00–10.00
sec
5-9
E1-01
Input Voltage
230
460
230: 155–255
460: 310–510
V
5-10
* Initial value is determined by O2-04 (kVA selection).
Summary of Contents for Impulse-t 2006-T
Page 2: ......
Page 7: ...C h a p t e r 1 Introduction...
Page 8: ...IMPULSE T Instruction Manual October 2015 1 2 This page intentionally left blank...
Page 14: ...IMPULSE T Instruction Manual October 2015 1 8 This page intentionally left blank...
Page 15: ...C h a p t e r 2 Installation...
Page 16: ...IMPULSE T Instruction Manual October 2015 2 2 This page intentionally left blank...
Page 21: ...C h a p t e r 3 Wiring...
Page 22: ...IMPULSE T Instruction Manual October 2015 3 2 This page intentionally left blank...
Page 33: ...C h a p t e r 4 Getting Started...
Page 34: ...IMPULSE T Instruction Manual October 2015 4 2 This page intentionally left blank...
Page 44: ...IMPULSE T Instruction Manual October 2015 4 12 This page intentionally left blank...
Page 45: ...C h a p t e r 5 Programming Features...
Page 46: ...IMPULSE T Instruction Manual October 2015 5 2 This page intentionally left blank...
Page 69: ...C h a p t e r 6 Troubleshooting...
Page 70: ...IMPULSE T Instruction Manual October 2015 6 2 This page intentionally left blank...
Page 77: ...A p p e n d i x A Advanced Parameter Listing...
Page 78: ...IMPULSE T Instruction Manual October 2015 A 2 This page intentionally left blank...