IMPULSE•T Instruction Manual – October 2015
5-13
Terminal Parameters
There are both digital and analog inputs and outputs that can be programmed for customized
operation and sequencing. These include input and output terminal selection along with serial
communication. Listed below are the parameters in this section that are customizable for your
system.
•
H1 Digital Inputs
•
H2 Digital Output
•
H3 Analog Input
•
H4 Analog Output
Digital Inputs
The IMPULSE•T has five multi-function contact inputs for the set-up of numerous functions. The
following table lists the function selections for the multi-function contact inputs (terminals S1 to S5)
and indicates the control modes during which each function can be enabled. An OPE03 error will
occur if a function is programmed in more than one terminal at the same time.
Table 5-16:Digital Inputs Parameter Settings
Parameter
Code
Name
Function
Reference
Page
Number
Range
Initial
Value
Access
Level
H1-01
Terminal S1 Select
Selects the multi-function
inputs. Setting for S1.
--
00–81
80
Adv
H1-02
Terminal S2 Select
Setting for S2.
--
00–81
81
Adv
H1-03
Terminal S3 Select
Setting for S3.
--
00–81
00
Adv
H1-04
Terminal S4 Select
Setting for S4.
--
00–81
01
Adv
H1-05
Terminal S5 Select
Setting for S5.
--
00–81
0F
Adv
00 Multi-Step Ref 2
Multi-Step Speed 2. (B1-02)
5-3
01 Multi-Step Ref 3
Multi-Step Speed 3. (B1-03)
5-3
02 Multi-Step Ref 4
Multi-Step Speed 4. (B1-04)
5-3
05 Accel Command
Acceleration function (2nd
step of Two-Step Infinitely
Variable or 3rd step of
Three-Step Infinitely
Variable).
5-3
0F Not used
No function - terminal is
disabled
--
20 thru 2FExternal Fault
Desired setting is possible.
Input mode: N.O./N.C.,
Detection mode: Always/
During Run (See external
fault response selection
Table 5-17)
5-14
32 Ext BB N.O.
N.O.: Baseblock by ON.
Immediate stop at STOP
command; normally open
--
33 Ext BB N.C.
N.C.: Baseblock by OFF.
Immediate stop at STOP
command; normally closed
--
3F Fault Reset
Reset by ON
--
80 Forward Run
Forward Run Command
(B1-01)
5-3
81 Reverse Run
Reverse Run Command
(B1-01)
5-3
Summary of Contents for Impulse-t 2006-T
Page 2: ......
Page 7: ...C h a p t e r 1 Introduction...
Page 8: ...IMPULSE T Instruction Manual October 2015 1 2 This page intentionally left blank...
Page 14: ...IMPULSE T Instruction Manual October 2015 1 8 This page intentionally left blank...
Page 15: ...C h a p t e r 2 Installation...
Page 16: ...IMPULSE T Instruction Manual October 2015 2 2 This page intentionally left blank...
Page 21: ...C h a p t e r 3 Wiring...
Page 22: ...IMPULSE T Instruction Manual October 2015 3 2 This page intentionally left blank...
Page 33: ...C h a p t e r 4 Getting Started...
Page 34: ...IMPULSE T Instruction Manual October 2015 4 2 This page intentionally left blank...
Page 44: ...IMPULSE T Instruction Manual October 2015 4 12 This page intentionally left blank...
Page 45: ...C h a p t e r 5 Programming Features...
Page 46: ...IMPULSE T Instruction Manual October 2015 5 2 This page intentionally left blank...
Page 69: ...C h a p t e r 6 Troubleshooting...
Page 70: ...IMPULSE T Instruction Manual October 2015 6 2 This page intentionally left blank...
Page 77: ...A p p e n d i x A Advanced Parameter Listing...
Page 78: ...IMPULSE T Instruction Manual October 2015 A 2 This page intentionally left blank...