Flex 8EX EU System Instruction Manual
March 2012
23 of 37
b. Non-Interlocked Functions
Contrary to interlocked settings, non-interlocked settings allow the two adjacent push
buttons be used simultaneously. Non-interlocked settings are usually applied to a
crane’s auxiliary functions such as lights, horns, 3
rd
speed, auxiliary stops and Pitch &
Catch. Each dip-switch on the decoder module corresponds to one (1) motion or two
(2) adjacent push buttons (left & right push buttons).
Function
Code
Dip
Position
Setting
#1
Dip Position Setting
#2 - #4 (left button)
&
#5 - #7 (right button)
Function Description
A 1
000
Normal (momentary) contact.
B 1
001
Toggled (latching) contact.
C 1
010
Acceleration (3
rd
speed).
D 1
100
Start function. For added safety,
you must first rotate and hold the power key
switch at “START” position and then press
the intended push button at the same
time to activate the output relay.
E 1
110
Pitch & Catch
F 1
111
Auxiliary Stop.
Example #1: Left button (set to function code A) / right button (set to function code A)
→
1
000 000
Example #2: Left button (set to function code B) / right button (set to function code B)
→
1
001 001
Example #3: Left button (set to function code A) / right button (set to function code C)
→
1
000 010
Example #4: Left button (set to function code F) / right button (set to function code A)
→
1 110 000
Note:
When set to Pitch & Catch function, make sure the 2
nd
transmitter is set to the next upper channel. For
example, if the system is preset at Ch.01, then the 2
nd
transmitter should be set to Ch.02. Furthermore,
you must also set the dip-switch on the receiving module (position #7 & #8) to “10” position (2-channel
scanning), please refer to page 21.
Note:
When set to “Auxiliary Stop” do make sure that JP3 is inserted (refer to jumper settings next page).