![Magnescale MG80-PN Operating Manual Download Page 52](http://html1.mh-extra.com/html/magnescale/mg80-pn/mg80-pn_operating-manual_3565527052.webp)
51
(24)
Master preset call instruction command
Offset
Label
Setting value (Hex)
0
INC
Please enter an arbitrary value different from the value previously
sent.
1
CMD
0x1B
2
RSV1
0x00
3
RSV2
0x00
4
DATA1
※
ASCII code
Axis number
Setting value
(Hex)
‘
1
’~’
10
’
0x30
~
0x39
‘
11
’~’
16
’
0x41
~
0x46
5
~
15
DATA2
~
DATA11
Dummy
0x00
(25)
Start instruction command
Offset
Label
Setting value (Hex)
0
INC
Please enter an arbitrary value different from the value previously
sent.
1
CMD
0x1F
2
RSV1
0x00
3
RSV2
0x00
4
DATA1
※
ASCII code
Frame number
Setting value (Hex)
‘
A
’~’
J
’
0x30
~
0x39
‘
K
’~’
P
’
0x41
~
0x46
5~
15
DATA2
~
DATA11
Dummy
0x00